Cognitive Solutions A776 Manual De Usuario

Descargar
Página de 192
Chapter 5: Programming commands
50
A776 (B780) Programming Guide 
A776-PG00001 C 12/09
Set relative print position
ASCII 
ESC \ n1 n2 
Hexadecimal  1B 5C n1 n2 
Decimal 
27 92 n1 n2
Value of n:
To move the relative starting position right of the current position by n dots:
n1 =  Remainder after dividing n by 256 
n2 =  Integer after dividing n by 256
The values for n1 and n2 are two bytes in low byte, high byte word orientation.
To move the relative starting position left of the current position by n dots:
n1 =  Remainder after dividing (65,536–n) by 256 
n2 =  Integer after dividing (65,536–n) by 256
The values for n1 and n2 are two bytes in low byte, high byte word orientation.
Moves the print starting position the specified number of dots either right (up to the right margin) or left (up to the left 
margin) of the current position. The print starting position is reset to the first column after each line.
Formulas
To move to the left:
Determine the value of n by multiplying the number of columns to move left of the current position by 10 (slip  
or receipt standard pitch) or 8 (receipt compressed pitch). The example shows how to set the relative position two 
columns in standard pitch (10 dots per column) to the left of the current position.
2 x 10 =  
20 dots (two columns to be moved left of the current position) 
 
65,536–20 =  
65516 
 
65,516/256 =   255, remainder of 236 
 
n1 = 236, n2 =   255
To move to the right:
Determine the value of n by multiplying the number of columns to move right of the current position by 10 (slip 
or receipt standard pitch) or 8 (receipt compressed pitch). The example shows how to set the relative position two 
columns in standard pitch (10 dots per column) to the right of the current position.
2 x 10 =  
  20 dots (two columns to be moved left of the current position) 
20/256 =  
  0, remainder of 20 
n1 =  
  20, n2 = 0
Related information
If the set horizontal and vertical minimum motion units command (1D 50) is used to change the horizontal and vertical 
minimum motion unit, the parameters of this command (set relative print position) will be interpreted accordingly. For 
more information, see the description of the set horizontal and vertical minimum motion units command (1D 50) in 
this document. 
Compatibility information (A776 receipt vs. A756 receipt)
There is a difference in the normal behavior of this command as compared to the original A756. The difference 
exists when the command is used to move to the left. The A756 processes the whole print string prior to putting it 
in the buffer for the printhead. This method of processing allows the A756 to backup in the print string and replace 
characters and their associated attributes when a “Set relative print position” command instructs the printer to move 
the print position to the left.
In order to improve the speed of printing, the A776 moves the data into a buffer for the printhead when it receives 
it. When the “Set relative print position” command contains a move to the left, this causes the new data to overstrike 
the previous data. This behavior can be used to an application’s advantage to provide the ability to create compound 
characters on the receipt station.