Cabletron Systems 510 Manual De Usuario

Descargar
Página de 106
A-7
Problem Solving
Problem Solving Using the LEDs
When diagnosing a problem with the router, note that the problem is often 
indicated by the states of the router’s LEDs. Table A-3 lists the states of the 
LEDs for various error conditions that can occur during initial installation of 
the device, along with probable causes and corrective actions to take.
Table A-3. LED States
Symptom
Probable Cause
Corrective Action
All LEDs are 
off.
The router does not 
have power.
Secure the power cables at the 
back cover and between the 
power supply and wall outlet.
Check the wall outlet using 
another appliance or light, or 
plug the power cord into 
another outlet. If no power is 
available, check the wall 
outlet’s circuit breaker.
Replace the power supply or 
the router if the problem 
persists.
Wrong power supply.
Ensure to use only the 
H8767-AA power supply.
Power LED only 
is off.
Bad Power LED.
Replace the router.
Module OK 
LED is off.
Self-test failed.
If the LED does not light after 
5 seconds, reset the router to 
repeat the self-test. 
Check console and reload 
flash.
If the self-test fails again, 
replace the router.
Continued on next page ...