Configure the other settings as required on the AP. The table below explains the
other settings.
other settings.
Configuring the Dial-Up System
To configure the Dial-up System, (assuming the PPP, serial port, and answer mode
are enabled on the AP), follow the procedure below.
are enabled on the AP), follow the procedure below.
1 Attach a null-modem serial cable from the AP to the modem.
2 Verify the modem connects to the telephone line and has power. Refer to the
modem documentation for information on verifying device power.
3 Start the communication program from the remote terminal.
4 Select the correct serial port along with the following parameters:
■
Emulation—ANSI
■
Baud rate—19200 bps
■
Data bits—8
■
Stop bits—1
■
Parity—none
■
Flow control—none
5 Dial out to the AP with the appropriate telephone number. No password is required.
6 Press Esc to refresh the display.
The AP displays the Main Menu.
Hanging Up
To hang up from the UI while a call is still connected:
1 Select Special Functions from the Main Menu.
2 Select Modem Hangup.
Setting
Description
Answer Wait Time
The time waiting for a remote
connection before dropping the
attempt. The default is 60 seconds.
connection before dropping the
attempt. The default is 60 seconds.
Modem Speaker
AP sends a command to the modem to
turn on/off the modem speaker. The
default is On.
turn on/off the modem speaker. The
default is On.
Inactivity Timeout
The inactivity time on the UI that causes
the AP to terminate the connection
while using a modem. The default is 5
minutes. A value of zero indicates no
time-out.
the AP to terminate the connection
while using a modem. The default is 5
minutes. A value of zero indicates no