Cabletron Systems 3Com Manual De Usuario

Descargar
Página de 93
Configuring the AP
67
Dial out manually through the Special Functions menu or dial out automatically 
when the system boots up.
Originating AP
To configure an originating AP, do the following from the UI of the originating AP:
Select Set Serial Port Configuration from the Main Menu.
Set the Port Use parameter to PPP.
Set the Modem Connected parameter to Yes.
Set the Connect Mode to Originate.
Select Dialout Number and type the dial-out telephone number of the answering 
AP (maximum 31 characters). 
This string matches what follows a typical Hayes Smartmodem ATDT command. 
Possible characters include pauses, numbers, and letters. Refer to your modem 
documentation.
Set the Dialout Mode to Auto.
Configure the remaining settings as required. 
Answering AP
From the answering APs UI:
Select Set Serial Port Configuration from the Main Menu.
Set the Port Use parameter to PPP.
Set the Modem Connected parameter to Yes.
Set the Connect Mode to Answer.
Configure the other required settings the same as on the originating AP.
Initiating Modem Connection
To manually initiate dial-out from the 
originating AP to the answering AP, do the following:
Select the Special Functions Menu from the Main Menu.
Select Modem Dialout.
The AP dials out and attempts to make a connection according to parameters set 
in the Serial Port Configuration. If dial-out fails, the AP switches to manual 
dial-out.
Parameter
Description
Answer Wait 
Time
Time in seconds waiting for a remote connection before dropping attempt. 
The default is 60 (range: 5 - 255)
Modem Speaker
Sends a command to the modem to turn the modem speaker on or off. The 
default is On.
PPP Timeout
Controls the time-out between issuing a PPP packet and the anticipated 
reply. This is necessary if the serial connection has long delay periods. Zero 
(0) indicates no time-out. The default is 3 from a 0 to 255-second range.
PPP Terminates
Controls the PPP terminate requests the AP issues when a PPP-linked AP 
does not respond to a terminate request. The AP closes the PPP connection 
after making the maximum requests. The default is 10 from a 0 to 
255-terminate request range.