12. Convert Refractory Kit to Fit B-Vent Appliance
a.  Locate the back refractory piece and lay the brick side down 
on a fl at surface. Locate the indicator marks on the back 
of the refractory piece. Lay a straight edge on the indicator 
marks and cut with a utility knife. See Figure 8.
Figure 8 
(back of Herringbone refractory)
(bottom for b-vent)
Figure 9
(back of Traditional refractory)
(bottom for b-vent)
Figure 10 
b.  B-Vent/Herringbone - cut at line, discard lower (smaller) 
portion. Install cut side down. Refer to Figure 9.
c.  Direct Vent/Herringbone - Install whole refractory.
d.  B-Vent/Traditional - cut at line, discard upper (smaller) 
portion. Install cut side down. Refer to Figure 10.