INSTALLATION 
 
9
 
2.8.2 
Network Cabling 
 
The Multidrop line is made using RJ45 connectors and a cable having the following 
specifications: 
• 
twisted pair AWG 24 wires 
• 120 
Ω impedance 
• 
maximum network cable length 1200 meters 
 
Pin Function 
Multidrop 
Cables
 
1 RS-485 
2 RS-485 
3 N.C. 
4 VDC 
– 
5 VDC 
– 
6 N.C. 
7 VDC 
8 VDC 
 
 
 
 
 
 
 
RJ45 
5
2
RJ45 
1
VDC- 
RS-485- 
RS-485+ 
Twisted Pair – RS-485 bus
 
 
8
5
2
RJ45
RJ45 
1
Twisted Pair – RS-485 bus 
Twisted Pair - Power supply 
VDC+
VDC-
RS-485-
RS-485+
 
 
When wiring the multidrop cables, note the following: 
 
Pin 8 (or 7) can be connected only if the power has to be propagated from a cradle to a 
STARGATE™ base station or STAR-Box™ converter via the cable. 
 
Pins 5 (or 4) should always be connected as reference ground. 
 
To avoid excessive voltage drop, it is recommended not to propagate power between 
BC-8060 cradles when used as battery chargers but to supply each cradle 
individually. The total number of devices, which can be connected to a single power 
supply, depends on the power supply voltage, the wire length and resistance and 
therefore the voltage drop. Do NOT connect VDC+ between network devices that are 