Programming Function Blocks and Features 
 
Video Recorder – User Manual 
 
136
Scaling 
The output CVn OV is a linear scaling of the input using the specified limits. 
Table 4-43 describes the Scaling prompts. See Table 4-2 for additional prompts. 
 
Table 4-43   Scaling Prompts 
 
 
Prompt 
Range/Selections 
Definition 
IN LOW LIMIT 
IN HIGH LIMIT 
OFF or number 
Enter limits of input to be scaled. 
RANGE LOW 
RANGE HIGH 
OFF or number 
Enter the output’s scaling values and display limits.  Output 
is not clamped or flashed when it exceeds these limits. 
INPUT 
OFF, analog parameter, 
number 
Input to be scaled according to the limits.