12
 
Model Selection Guide (cont.) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
VRX180
TABLE V - OPTIONS (continued)
Selection
Approvals
CE Mark Compliant
_ _ _ 0 _ _
CSA/NRTLc/CE Mark
_ _ _ C _ _
Software
None
_ _ _ _ 0 _
SDA and SCF
_ _ _ _ B _ 
SCF (Configuration Software)
_ _ _ _ C _
SDA (Data Analysis Software)
_ _ _ _ E _
Case
Galvanized Case, Grey Door, Glass Window, Latch
_ _ _ _ _ 0
Galvanized Case, Grey Door, Glass Window, Key Lock
_ _ _ _ _ 1
Galvanized Case, Grey Door, Plastic Window, Latch
_ _ _ _ _ 2
Galvanized Case, Grey Door, Plastic Window, Key Lock
_ _ _ _ _ 3
Portable Case (Painted Case, Handles)
_ _ _ _ _ 6
TABLE VI
Factory Use Only
00
SOFTWARES AND SUPPORT PARTS
Part #
SDA Data Analysis Software (can be ordered separately if not selected in Table V)
045501
SCF Configuration Software (can be ordered separately if not selected in Table V)
045502
SDI Disk Initialization Software 
(Note 6)
46193351-501
Kit of 4 resistors 250 Ohms for 4-20 mA input
46181080-503
RESTRICTIONS
Restriction Letter
Available With
Not Available With
Table
Selection
Table
Selection
c
II
_ _ _ _ _ A, _ _ _ _ _ B, _ _ _ _ _ C, 
_ _ _ _ _ E,  _ _ _ _ _ R, _ _ _ _ _ G,
_ _ _ _ _ H,  _ _ _ _ _ M
Notes:
1. The available algorithms include: PID (standard and advance), Cascade, Split Output and On/Off.
The appropriate outputs from Table I must be specified - Current or Relays.
If Split (Duplex) output Control is required, advance math must be selected ( Table III  ).
2. Standard Math includes 24 Calculated Values and the following pre-packaged algorithms
Free Form Math
Logic Operators
Flip-Flop/One Shot
Periodic Timer
Free Form Logic
Math Operators
Invertor
Advance Math includes 64 Calculated Values and the following additional of pre-package algorithms.
Signal Select
Interval Timer
Counter
Compare
Relative Humidity
Scaling
Signal Clamp
Mass Flow
Advanced Splitter
Peak Picking
Fo Calculation
Continuous Emissions Monitoring
Function Generator
Multiple Input Average
  -  CEM Block Average
Carbon Potential
Single Point Average
  -  CEM Rolling Average
Rolling Average
Standard Splitter
3. Customer must supply Input Actuation Type and Range for each input for inclusion in the free form
section of the Factory order to supply the Custom Calibration Certificate, otherwise the calibration will be 
based on the factory default ranges.
4. When selecting SP program make sure to select analog output (current) as necessary (Table II slot N,P).
5. When selecting Control loops, make sure to select outputs (as necessary in Table II)
6. Provided with each VRX180 are : one pre-initialized disk and one SDI software pack.
SDI software should be installed on a PC and used for initialization of new disks.
7. Must purchase Table II _ _ _ _ M _  in order to select Table II Selection _ _ _ _ _ M.