Installation 
 
Video Recorder - User Manual 
33 
2.5.7.4  Connecting the RS422/485 link to a computer 
 
The VRX180 video recorder with the RS422/485 Communications option can be connected your 
computer using one of two arrangements : 
 
•  Wired to an RS422/485 compatible serial port (if the computer is equipped with such a port). 
•  Wire the RS232 serial port of the computer to an RS232 to RS485 converter. The RS485 port 
of the converter should be wired to the Communications port of the VRX recorder. 
 
Arrangement
 
ICS plug-in I/O board 
Description
 
Wired directly to the RS422/485 port in your computer using an ICS plug-
in I/O board which is specifically designed to interface with the IBM (or 
IBM compatible) PC, PC/XT; or PC/AT computer. 
 
This board is available from... 
ICS Computer Products, Inc. 
5466 Complex Street 
Suite 208 
San Diego, California 92123 
Burr-Brown Converter 
Using the RS232 port a Burr-Brown RS232 to RS422/485 converter 
installed between the RS232 port and the video recorder. 
 
This converter is available from : 
Burr-Brown 
International Airport Industrial Park 
P.O. Box 11400 
Tucson, Arizona 85734 
Part number LDM485ST, limited distance modem 
Westermo converter 
The Westermo MA44 converts RS232 to RS422/485. It is installed 
between the RS232 port and the video recorder.  
2.5.7.5 Rear connection  
The video recorder has built in circuits to reduce the effects of most electrical noise. We recommend 
that you review the following guidelines, to minimize the noise effects. 
 
1.  Separate the communication leadwires from the line voltage, the alarm output, contactors, motors etc... 
2.  For a communication distance, over 1.5 meters, use a separate metal tray, or metal conduit. 
3.  Use wiring cable composed of twisted pair wirings, with a shield for RS485 and RS422. Use a shielded 
cable for RS232. 
4.  Connect the shield wire to the ground, at one end only, preferably at the video recorder. Use for example 
a wiring cable type: Belden 9271 twinax, or equivalent. 
5.  We recommend to install a 120 ohms resistor between TXA and TXB, on the last video recorder on 
communication link. 
6. The maximum capabilities are: 
 
Type of communication 
Distances max. 
# of Unit 
RS232 
15 meters / 50 feet 
RS422 
1000 meters / 3280 feet 
15 
RS485 
1200 meters / 4000 feet 
31