Sterling XXX10-80 Manual De Usuario

Descargar
Página de 112
10-Pump, 80-Station Controller           Chapter 4: Operation 
52 
The following table explains the status represented by each color at the Station Status screen. 
Color Label 
Description 
Silver 
Offline 
Station is not enabled. The controller ignores any demands or 
alarms. 
Blue 
Ready 
Station is enabled and idle (full). 
Dark Yellow 
Demand 
Station requires material. 
Light Green 
Purging 
The material line is being purged of material. 
Brown 
Dumping 
The station is dumping material into its receiver. 
White 
Blow Back 
Station’s air filter is being cleaned by blowing compressed air 
backward through it. 
Dark Grey 
Bypass 
Bypass switch at the station has been turned on, disabling the 
station. 
Medium 
Green 
Priority 
Convey 
Station is in priority convey mode. Its pump will be temporarily 
dedicated to filling it as soon as possible. 
Orange 
Alarm 
Station is in alarm. 
Red 
Critical 
Station is in critical alarm. The controller has disabled the station 
until the alarm is cleared. 
Purple Closed 
Loop 
Station is in closed loop convey. 
Light Yellow 
Waiting 
Station is waiting for material to become available. 
Dark Green 
Convey 
Station is being loaded. 
 
Additional basic information about each station (convey time, dump delay, pump assignment, 
and, if enabled, RPV setting, purge settings, etc.) is available at the Station n Operator screen. 
See page 55 for details. 
Detailed configuration settings for each station are available at the Station n Setup screen. See 
page 39 for details. 
Reviewing Pump Status 
The Pump Status screen is the counterpart of the Station Status screen. To reach the Pump 
Status screen from any other screen: 
1.  Touch Pumps
 
The Pump Status screen appears: 
 
 
 
 
 
 
 
 
 
 
The status of each pump is color-coded, as summarized in the upper right of the screen. 
You can see a more detailed explanation of each status by using the online help. To do so 
from this screen: