10-Pump, 80-Station Controller 
Chapter 6:  Configurable Settings 
69 
Name Description 
Options 
Default 
# pulses 
Number of pulses of compressed air sent 
through the pump’s filter during cleaning. 
If blowback is not working as desired, the 
service department may ask you to change this 
setting. 
1–99 5 
On time 
Number of seconds that the air compressor 
remains on for each pulse during filter cleaning. 
If blowback is not working as desired, the 
service department may ask you to change this 
setting. 
0.1–99.9 sec.  1.0 sec. 
Off time 
Number of seconds between air pulses during 
filter cleaning. 
If blowback is not working as desired, the 
service department may ask you to change this 
setting. 
0.5–99.9 sec.  1.0 sec. 
Implosion with Seal 
Valve 
When this option is enabled, the controller 
builds a vacuum in the filter chamber by 
isolating it from the rest of the system with the 
sealing valve.  The vacuum is then released to 
dislodge dust and debris. 
 
 
Implosion without  
Seal Valve 
When this option is enabled, the controller 
builds a vacuum in the filter chamber by 
isolating it from the rest of the system by closing 
all the station sequence valves assigned to that 
pump.  The vacuum is then released to dislodge 
dust and debris. 
 
 
Every n Loads 
Number of conveying cycles to stations between 
filter cleanings. 
Adjust this setting based on experience. The 
more dust and debris in your material line, the 
smaller this number needs to be. 
1–99 5 
# Pulse(s) 
Number of pulses of compressed air sent 
through the pump’s filter during cleaning. 
If blowback is not working as desired, the 
service department may ask you to change this 
setting. 
1–99 5 
Vacuum Time 
Number of seconds allowed for the vacuum to 
build up in the filter chamber 
 
 
Release Time 
Number of seconds allowed for the vacuum in 
the filter chamber to dissipate.