10-Pump, 80-Station Controller           Chapter 7:  Troubleshooting 
72 
 
Alarm message  
Possible cause  
Pump X Option Output Conflict 
An assigned station has closed loop enabled and the pump has either 
implosion with sealing valve or Local Alarm enabled. 
Patch cord is cut or disconnected 
Purge Valve X Failure 
Solenoid has failed. 
ArmorBlock is not installed properly. 
ArmorBlock is not addressed correctly. 
ArmorBlock is defective. 
Purge Valve X Not Present 
ArmorBlock base is defective. 
Patch cord is cut or disconnected. 
Purge Valve X Power Failure 
Solenoid has failed. 
Pick up wand is not positioned properly. 
Take-off compartment is not adjusted properly. 
Receiver Level 
Leak in vacuum line. 
Patch cord is cut or disconnected. 
RPV Failure 
Solenoid has failed. 
Patch cord is cut or disconnected. 
Sequence Valve Failure 
Solenoid has failed. 
Patch cord is cut or disconnected. 
Slide Gate Failure 
Solenoid has failed.