Cisco Systems 186 Manual De Usuario

Descargar
Página de 218
 
C-2
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SIP)
OL-3410-01
Appendix C      Cisco ATA Specifications
Electrical Specifications
Electrical Specifications
Environmental Specifications
Immunity Specifications
EN50082-1, including the following:
EN61000-3-2, Electromagnetic Compatibility
EN61000-3-3, Electromagnetic Compatibility
EN61000-4-2, ESD
EN61000-4-3, Radiated Immunity
EN61000-4-4, Burst Transients
EN61000-4-5, Surge
EN61000-4-6, Injected RF
EN61000-4-11, Dips and Sags
Table C-2
Electrical Specifications
Description
Specification
Power
0.25 to 7.5W (idle to peak)
DC input voltage
+5.0 VDC at 1.5A maximum
Power adaptor
Universal AC/DC
~3.3 x 2.0 x 1.3 in. (~8.5 x 5.0 x 3.2 cm)
~4.8 oz (135 g) for the AC-input external power adaptor
~4 ft (1.2 m) DC cord
6 ft (1.8 m) cord
UL/CUL, CE approved
Class II transformer
Table C-3
Environmental Specifications
Description
Specification
Operating temperature
41 to 104
° F (5 to 40° C)
Storage temperature
–4 to 140
° F (–20 to 65° C)
Relative humidity
10 to 90% noncondensing, operating, and nonoperating/storage