Resecure, replace or correct as needed.
Remove pump module cover and inspect: 
•  Hydraulic hoses, fittings and connections for wear 
or leaks 
•  Harness cables, wires, terminals and connections 
for securement or damage
•  Control board, circuit breaker, power switch and 
lights for securement or damage
Resecure, replace or correct as needed
Use Braun 32840-QT (Exxon
®
 Univis HVI 26) 
hydraulic fluid (do not mix with Dextron III or other 
hydraulic fluids).  Check fluid level with platform 
lowered fully and roll stop unfolded fully.  Fill 
to within 1/2” of the bottom of the 1-1/2” fill tube 
(neck).
Tighten, repair or replace if needed. 
 
 
Tighten, repair or replace if needed.
 
Replace if needed. 
Tighten or replace if needed.
Replace defective parts and resecure as needed.  
Apply Light Grease during reassembly procedures.
Replace if needed.
Tighten, replace or correct as needed 
Apply Door-Ease or replace if needed.  See Lubri-
cation Diagram.
 
Resecure or replace if needed.     
Resecure, repair or replace if needed.
Check to see that the lift is securely anchored to 
the vehicle and there are no loose bolts, broken 
welds, or stress fractures.
Replace decals if worn, missing or illegible.  Re-
place antiskid if worn or missing.  
Perform all procedures listed in previous section also
1500 
Cycles
Repeat all previously listed inspection, lubrica-
tion and maintenance procedures at 750 cycle 
intervals.
Consecutive 
750 Cycle 
Intervals
4500 
Cycles
Inspect cotter pins on platform pivot pin (2)
Hydraulic Fluid (Pump) - Check level.  Note:  Fluid 
should be changed if there is visible contamination.  
Inspect the hydraulic system (cylinder, hoses, fit-
tings, seals, etc.) for leaks if fluid level is low.
Inspect cylinders, fittings and hydraulic connections 
for wear, damage or leaks 
Inspect outer barrier cylinder hose assembly (hose, 
fasteners, connections, etc.) for wear, damage or 
leakage
Inspect parallel arms, bushings and pivot pins for 
visible wear or damage
Inspect parallel arm pivot pin mounting bolts (8)
Inspect platform pivot pin, bushings and vertical 
arms for wear, damage and positive securement
Inspect upper/lower fold arms, rotating pivot slide 
arms, slide support arms and associated pivot pins, 
bushings, and bearings for visible wear or damage
Inspect gas springs (cylinders) for wear or damage, 
proper operation and positive securement (IB)
Inspect rotating pivot slide arm UHMW slide bear-
ings (buttons - 2) and UHMW slide ()
Inspect vertical arm plastic covers        
Inspect power cable 
 
 
Mounting 
 
 
 
 
 
 
Decals and Antiskid
Maintenance and Lubrication Schedule