Installation Instructions 
4
313848C
Installation Instructions
Pressure Relief Procedure
Follow this pressure relief procedure whenever you are 
instructed to relieve pressure or need to check or ser-
vice equipment.
1.
Turn off power (air, electric, hydraulic) to lube supply 
pump.
2.
Turn off air supply to air manifold.
3.
Using a wrench, slowly loosen fluid inlet fitting.
4.
Using a wrench, slowly loosen each outlet port fit-
ting.
5.
Using a wrench, slowly loosen air inlet fitting.
Assembly Instructions
NOTE: The Air Over Oil Manifold is designed to mount 
to a standard Graco MSP divider valve. For instructions 
on how to use an MSP divider valve, refer to instruction 
manual 312497. 
The Air Over Oil Manifold uses one-way air injectors to 
inject air into each of the individual divider valve lube 
outlet ports. Each air injector assembly is internally 
checked to prevent oil from entering the air supply sys-
tem. 
The Air Oil Valve does not utilize common porting 
between the lube outlets, therefore each outlet is both 
pneumatically and hydraulically independent. 
An air pressure sensor is provided to monitor for any 
blockage or breaks in the air line. 
The MSP divider valve can be used with a cycle indica-
tor to monitor for proper oil lube cycles or blockage in 
any of the lubrication lines.
1.
Remove alternate outlet port plugs from divider 
valves.
2.
Loosen valve mounting socket head cap screws.
3.
Place air over oil manifold over valves and hand 
tighten all air injectors to seat manifold on the valve 
stack. Then tighten air injectors with a wrench in a 
star pattern until all o-rings are seated in o-ring 
ports of valve and manifolds. 
NOTE: The correct order is provided in chart on 
page 3.
4.
Using valve mounting screw access ports, torque all 
valve mounting socket head cap screws  to 8 - 9 
foot/pounds (10.8 - 12.2 N•m).
5.
The air supply may be induced into manifold using 
available ports, A1, A2, A3, or A4.
6.
The air pressure sensor may be connected to any 
available port not connected to the air supply. This 
device warns of any blockage or breaks in the air 
line. 
NOTE: 
Always use an air line filter of 40 micron or better to 
remove dirt and moisture from the compressed air 
supply. 
Install an air regulator to allow pressure adjustment.
Start Up Instructions
System must be pre-filled with 100 psi (0.69 
MPa, 6.9 bar) of air pressure. Once system is 
pre-filled and oil is being emitted from each dis-
tribution line, system air may be reduced to final 
operating pressures.
Minimum operating air pressure is 45 psi (0.31 
MPa, 3.1 bar).
Air pressure sensors are factory set to 35 psi 
(0.24 MPa, 2.4 bar) (Models 24B237, 24B239, 
24B240, 24B241 only).