EasyKey Display and Keyboard
312779E
21
AC Power Switch
Turns system AC power on or off.
I/S Power
Power circuit to Fluid Station.
Potlife Exceeded Audible Alarm
Alerts the user when a Potlife Exceeded alarm occurs. 
Clear by pressing the Alarm Reset 
 
key.
Graco Web Interface Port
Used to communicate with the ProMix from a PC to:
➜ Upgrade software
➜ View software version
➜ Download 
• Job and alarm logs
• Material usage report
• Setup values (can also upload)
➜ Clear job, alarm, and material usage reports
➜ Upload a custom language to view on 
screen
➜ Restore factory defaults
➜ Restore setup password
See manual 313386 for more information.
NOTE: If using the Graco Gateway in your system, dis-
connect its cable from the EasyKey before updating the 
ProMix 2KS software.
Ethernet Connection
You can access data on an office or industrial network 
through the internet with the proper configuration. See 
manual 313386 for more information.
F
IG
. 8. EasyKey Connections and AC Power Switch
AC Power 
Switch
Graco Web 
Interface
Audible Alarm
Fiber Optic Strain 
Relief Port
I/S Power
Discrete I/O Cable 
Connector Ports
Ground Screw
Main Power 
Access Port
TI12638a
TI12657a