Datalogic Scanning D8330 Manuel D’Utilisation

Page de 212
POWERSCAN
®
 D8330/M8300 
 
22   
 
3.2.2 
BC-8060 Master Layout 
 
 
 
 
A. Host 
B. BC-8060 
Master 
cradle 
C. BC-8060 
Slave 
cradles 
D.  STARGATE™ base station 
Example Multidrop STAR-System™ Network with BC-8060 as Master 
 
In this layout an BC-8060 cradle acts as the Master. The Host is connected to the  
BC-8060 Master using any one of the multi-standard interfaces (RS-232, USB, 
WEDGE, or PEN Emulation). The Master is then connected to the slaves in the RS-485 
network. In this way the slave cradles provide communications between a single Host 
and all readers in the system. STARGATE™ base stations can also be used as slaves 
in this network. The devices at the ends of the network must be terminated (see par. 
2.8.3). 
 
See pars. 4.6 and 4.7 or the Datalogic Aladdin™ Help On-Line for system 
configuration specifications. 
 
Internal 
Termination
Internal
Termination
RS-485 + VDC 
RS-485 Only 
USB, or RS-232, or Wedge, or Pen Emulation 
A
B
C
D
RS-485 Only 
CAB-428 Splitter