Emerson Process Management 3051N Manuel D’Utilisation
Reference Manual
00809-0100-4808, Rev CA
June 2008
June 2008
A-3
Rosemount 3051N
FIGURE A-1. HART Communicator Typical Abbreviated Menu Tree for Rosemount 3051.
1 DEVICE
SETUP
2 PV
3 AO
4 LRV
5 URV
1 PROCESS
VARIABLE
2 DIAGNOSTICS
AND SERVICE
3 BASIC SETUP
4 DETAILED
SETUP
5 Review
Online
Menu
1 Pressure
2 Percent Range
3 Analog Output
4 Sensor
Temperature
1 TEST DEVICE
2 Loop Test
3 CALIBRATION
1 Self Test
2 Status
1 RERANGE
2 TRIM ANALOG
OUTPUT
3 SENSOR TRIM
7 METER OPTS.
1 SENSORS
2 SIGNAL
CONDITION
3 OUTPUT
CONDITION
4 DEVICE
INFORMATION
4 RECALL
FACTORY TRIM
1 Keypad Input
2 Apply Values
1 Digital-to-Analog Trim
2 Scaled D/A Trim
1 Zero Trim
2 Lower Sensor Trim
3 Upper Sensor Trim
4 Sensor Trim
Calibration Type
5 Sensor Trim Points
1 Sensor Trim
2 Analog Output Trim
1 Keypad Input
2 Apply Values
1 Date
2 Descriptor
3 Message
4 Write Protect
1 Tag
2 Unit
3 RANGE VALUES
4 DEVICE INFO
5 Transfer Function
6 Damp
1 Meter Type
2 CUSTOM
METER SETUP
1 PRESSURE
SENSOR
2 TEMP SENSOR
1 Sensor Temp
2 Temperature Unit
1 Sel Dec Pt Pos
2 CM Upper Value
3 CM Lower Value
4 CM Units
5 CM xfer function
1 PROCESS VARIABLE
2 SENSOR SERVICE
3 Unit
1 Pressure
2 % Range
3 Sensor Temp
1 SENSOR
TRIM
2 Recall
Factory
Trim
Trim
1 Zero Trim
2 Lower
Sensor Trim
3 Upper
Sensor Trim
4 Sensor Trim
Calibration
Type
Type
5 Sensor Trim
Points
1 PROCESS
VARIABLE
2 RANGE
VALUES
3 Unit
4 Transfer Func
5 Damp
6 Snsr Temp Unit
7 ALM/SAT
LEVELS
1 PROCESS
VARIABLES
2 ANALOG
OUTPUT
3 HART OUTPUT
4 METER
OPTIONS
1 FIELD DEVICE
INFO
2 SENSOR INFO
3 Self Test
4 DIAPHRAGM
SEALS INFO
1 Pressure
2 % Range
3 Snsr Temp
1 Keypad Input
2 Apply Values
1 High Alarm
2 Low Alarm
3 High Saturation
4 Low Saturation
5 AO Alarm Type
6 Alarm/Sat Type
1 Pressure
2 % Range
3 Analog Output
4 Sensor Temp
1 Loop Test
2 Digital-to-Analog Trim
3 Scaled D/A Trim
4 AO Alarm Type
1 Poll Address
2 Nos. of Req. Pream.
3 Burst Mode
4 Burst Option
1 Meter Type
2 CUSTOM METER
SETUP
3 Custom Meter Value
1 Measurement Type
2 Mod. Config. Type
3 Isolator Material
4 Fill Type
5 Proc. Conn. Type
6 Proc. Conn. Material
7 O-Ring Material
8 Drain/Vent Material
1 Sel. Dec. Pt. Pos.
2 CM Upper Value
3 CM Lower Value
4 CM Units
5 CM xfer function
1 Tag
2 Date
3 Descriptor
4 Message
5 Model
6 Write Protect
7 Local Keys
8 REVISION #S
9 Final Assy #
10 Device ID
11 Distributor
1 Univ.
Rev.
2 Fid. Dev.
Rev.
3 S/W Rev.
1 # of Diaphr. Seals
2 Diaphr. Seal Type
3 Diaphr. Seal Fill
4 Diaphr. Material
NOTE
“3051” will appear in the upper left of the
communicator screen when this menu tree is valid.
“3051” will appear in the upper left of the
communicator screen when this menu tree is valid.