Crown Audio I-T5000 HD Manuel D’Utilisation

Page de 60
I-Tech HD Series Power Amplifi ers
Operation Manual
page 17
Presets: A preset is a group of DSP and amplifi er settings for a particular 
speaker system. Turn an Encoder to view Presets 1 through 50. To recall a 
preset, press the Encoder, then press and hold the Encoder to confi rm. For 
more information on presets, see Section 4.3.
The preset currently in use is displayed in the upper right corner. 
(A) Active means that the amplifi er is operating exactly according to that 
preset.
(M) Modifi ed means that the amplifi er is operating according to the preset 
but with some settings changed.
If a preset number is fl ashing, it is not in use.  
In the example shown below, 
• Preset 7 is in use (it’s in the upper right corner).
• The amplifi er settings have been modifi ed (M) since Preset 7 was loaded.
• The large “7” is not fl ashing, which means that Preset 7 is in use.
Locate: Allows users to identify a specifi c amplifi er in a large network of 
amplifi ers without having to compare address infor mation. Locate can be 
turned on/off from software and/or the front panel. Press an Encoder knob to 
turn on the Locate function. When on, the LCD screen fl ashes. Press the knob 
again to turn off the Locate function. In System Architect, the device icon has a 
blue outline to indicate that it is in Locate mode.
4 Advanced Operation
In the example shown below, you turned down an Encoder knob two notches 
after load ing Preset 7.
• Preset 7 is in use (it’s in the upper right corner).
• Preset 7 is active (A). That means the amplifi er is operating exactly according 
to that preset.
• The large “   5” is fl ashing because Preset 5 is not in use.
• Preset 5’s Channel-1 label is “LF–1&2.”
• Preset 5’s Channel-2 label is “LF–3&4.”
Sample Rate: Starting from the Attenuation screen, press Menu/Exit to go 
to the Sample Rate screen. The sample rate of the amplifi er’s DSP is displayed. 
It can be modifi ed only in System Architect software because all of the FIR fi lter 
settings will need to be recalculated as a result of the change. Please refer to its 
Help fi les. When you route a Cobranet input, the sample rate displayed here 
must match the Cobranet source.
96 kHz
Sample Rate      
Sample Rate      
Modify in software ONLY!      
Modify in software ONLY!      
Analog Input Sensitivity: Turn the left Encoder knob to change the Ch. 1 
input sensitivity; turn the right Encoder knob to change the Ch. 2 input 
sensitivity. This screen also displays the amp gain for each channel resulting 
from the sensitivity settings. See Figure 4.4.
Note: If you do not see the sensitivity you need, try changing the Maximum 
Analog Input level in the Advanced Menu (described later). This makes 
different sensitivities available.
To optimize the system gain structure, see Section 3.1 in the I-Tech application 
Guide at www.crownaudio.com/itech/pdf/137327.pdf.
2.90
Analog Input Sensitivity      
Analog Input Sensitivity      
   
   
31.5
2.90
31.5
Vrms
dB Gain
Amp Mode: This screen lets you set up the amplifi er for Dual, Input Y or 
Bridge Mono mode. Turn an Encoder knob to choose among those three 
options, then press the knob to save your choice. You will be prompted to 
confi rm your choice. The LCD screen displays the currently selected mode.
In Dual (or Stereo) mode, both channels operate independently.
In Bridge Mono mode, both channels are summed to double the power, and the 
amplifi er puts out a mono signal.
In Input Y mode, Channel 1’s input signal feeds both channels, and each 
channel can be set to a different output level, usually for bi-amp operation.
      <Dual>
Amp Mode      
Amp Mode      
   
   
Turn to Set-Press to Save
7
Presets         Preset7 (M)   
Presets         Preset7 (M)      
   
   
CH
1:MF-1&2
CH
2:MF-3&4
Preset7
5
Presets         Preset 7(A)      
Presets         Preset 7(A)      
   
   
CH
1:LF-1&2
CH
2:LF-3&4
Preset7
4.2.3 ADVANCED MENU
When you see this screen, press an Encoder knob to access the selections in  
the Advanced Menu, described next. To get to the Advanced Menu screen from 
the Attenuation screen, press Menu/Exit twice, then press Next fi ve times.
Advanced Menu
Advanced Menu      
Advanced Menu      
   
   
Push knob for adv. menu
OFF
Locate      
Locate      
   
   
Press enc to toggle