Vent system chart
NOTE: Performance of rear exhaust to either side of the dryer is 
equivalent to adding one elbow. To determine maximum exhaust 
length, add one elbow to the chart.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior 
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust 
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible. 
See “Determine vent path” in “Plan Vent System.” Avoid 90º 
turns. Use clamps to seal all joints. Do not use duct tape, 
screws or other fastening devices that extend into the interior 
of the vent to secure vent.
Install Leveling Legs
1. To protect the floor, use a large, flat piece of cardboard from 
the dryer carton. Place cardboard under the entire back edge 
of the dryer. 
2. Firmly grasp the body of the dryer (not the top or console 
panel). Gently lay the dryer on the cardboard. See illustration.   
3. Examine the leveling legs. Find the diamond marking. 
4. Screw the legs into the leg holes by hand. Use a wrench to 
finish turning the legs until the diamond marking is no longer 
visible.
5. Place a carton corner post from dryer packaging under each 
of the 2 dryer back corners. Stand the dryer up. Slide the 
dryer on the corner posts until it is close to its final location. 
Leave enough room to connect the exhaust vent.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in 
dryer. If connecting to existing vent, make sure the vent is 
clean. The dryer vent must fit over the dryer exhaust outlet 
and inside the exhaust hood. Make sure the vent is secured 
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Make sure that there are no kinks in the 
flexible gas line.
4. Once the exhaust vent connection is made, remove the 
corner posts and cardboard.
Level Dryer
Check the levelness of the dryer by first placing a level on the top 
of the dryer near the console.  
Then, by placing a level in the crease on the side of the dryer 
between the top of the dryer and the dryer cabinet, check the 
levelness from front to back.
If the dryer is not level, prop up the dryer using a wood block. 
Use a wrench to adjust the legs up or down and check again for 
levelness.
Number of 
90º turns 
or elbows
Type of
vent
Box or 
Louvered 
hoods
Angled
hoods
0
Rigid metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1
Rigid metal
Flexible metal
54 ft (16.5 m) 
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2
Rigid metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3
Rigid metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4
Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.