ARRI 416 Manuel D’Utilisation

Page de 240
1
11.Timecode
The ARRIFLEX 416 is equipped with a TC generator which 
produces 80bit Timecode with a data structure conforming 
to SMPTE RP136, Format Type C. The TC generator is set 
using a master clock. The precision of the TC generator 
ensures that for 8 hours after the synchronization (at 0°C 
- 50°C) the difference remains less than one frame, if the 
time code generator of the audio machine is precise, too. 
Every frame is therefore clearly identifiable for synchro-
nization or editing lists. 
A new feature on the 416 further improves the accuracy 
of the synchronization between the 416 TC generator and 
the master clock. To exploit this feature the camera must 
be connected to an Ambient Clockit as the master clock.
Timecode is recorded in the magazine, its position on film 
conforming to SMPTE RP114, at standard speeds of 
23.976, 24.00, 25.00, 29.97 and 30.00 fps.
The TC information also includes speed of recording 
which is described in connection with Timecode as frame 
rate. For the ARRIFLEX 416 the valid frame rate is always 
the most recently set standard speed.
For Timecode operation, please make sure that 
the magazine is equipped with a Timecode 
exposure module K2.55034.0.
TC-Input 
The TC generator integrated in the ARRIFLEX 416 can be 
synchronized to other equipment with a TC generator. A 
LTC signal (Longitudinal TimeCode) from any TC generator 
is plugged into the “TCC“ socket. The signal level must be 
higher than 500 mV p-p. The camera automatically takes 
on TC time and TC User Bits. If the LTC signal is correctly 
transferred the TC recording will be automatically 
switched on.
Timecode