The frame rate of the camera is constantly monitored while 
it is running. If the actual frame rate deviates from the set 
frame rate, the operation control indicator glows red, a 
red LED is seen in the viewfinder and the camera display 
shows the warning for asynchronous running (“asy”).
Fuses 
The ARRIFLEX 416 is equipped with self-resetting 
automatic fuses. There are no conventional fuses to blow.
If one of the self resetting fuses blows, turn the camera off, 
unplug  all accessories from the camera, wait for one 
minute, and turn the camera back on.