Better Light 7 Manuel D’Utilisation

Page de 99
50
Color Panel
Color balance adjustments are used to neutralize 
unwanted color casts, and also to introduce intentional 
color casts for mood or effect. ViewFinder™ allows the 
photographer to adjust color balance in increments of 
0.1 CC (color correction units), and also provides an 
automatic balancing function for rapid neutralization 
of colors under any lighting conditions. Color balanc-
ing is accomplished by changing the effective sensitiv-
ity of each of the three color channels, rather than by 
altering the effective exposure time of each color chan-
nel or by post-manipulation of the camera data. This 
superior method of achieving color balance does not 
suffer from the side effects of other methods (color 
fringing from different exposure times, or posterization from insufficient camera data).
Establishing Neutral Color Balance
The easiest method for color balancing an image starts by including a known neutral object in the 
prescan. The Macbeth ColorChecker™, a set of gray patches made from pigmented materials, or the 
plastic Digital Gray Card™ (available from rmimaging.com), is recommended over the common pho-
toprint “gray card”, or photographic gray scale, which can behave inconsistently under different light-
ing conditions. The neutral object should be evenly illuminated by the primary lighting on the set, as 
all lights may not have exactly the same color, especially if modifiers are used on some lights.
The Default setting, or a previously-determined color balance setting for a similar type of lighting, 
can be selected from the popup menu. Using one of the appropriate settings makes your first prescan 
closer to neutral, minimizing the changes needed.
 
Recommended RGB values for an 18% gray should be within approximately 85 to 130. 
But values for doing a Color Balance may extend higher in value, perhaps 85 to 200, as 
long as the gray is in the linear portion of the tone curve, and not in the shoulder area 
where data values tend to compress relative to intensity changes. 
After performing a prescan, make sure the spot meter is cleared (no recorded “spots” -- use Com-
mand-M (Macintosh) or Control-M (Windows) to clear the meter or go to the Color tab panel and 
click on the Clear Meter button). Select the Spot Meter tool (the   button is selected on the tool bar 
at the top of the window), then move the spot meter cursor over the gray patch in the preview image 
and click once to record a spot meter location.
Color tab panel with static spot meters and neutral values 
before Auto Balancing.