Mitsubishi Electronics FX3GC Manuel D’Utilisation

Page de 964
49
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
1
Introdu
ction
2
Ov
ervi
ew
3
Instruction 
Li
st
4
D
evices 
in Det
ai
l
5
Specifi
ed the
De
vice
 &
 
C
onst
ant
6
Bef
ore
 
Pr
og
ra
mmi
ng
7
Bas
ic 
Instruction
8
FN
C00-FN
C0
9
Program Fl
ow
9
FNC
10-FN
C19
Mov
e & Com
pare
10
FNC
20-FNC
29
Arith. & Lo
gi
Operati
on
3. FX
3U
/FX
3UC
 PLCs
Caution
• The  FX
3U
/FX
3UC
 PLCs can store symbolic information in the following capacity:
- The  FX
3U
-FLROM-1M (memory cassette) has an area dedicated to the storage of symbolic information, and can 
store up to 1300 kB.
- When storing the symbolic information in any memory cassette other than the FX
3U
-FLROM-1M or to the built-in 
memory, make sure that amount of the symbolic information to be stored does not exceed the available memory 
capacity.
It is recommended to use the FX
3U
-FLROM-1M when there is a large amount of symbolic information to be 
stored.
Symbolic information capacity = Maximum capacity of memory cassette - Memory capacity set by parameters
It is possible to check the symbolic information capacity using the memory capacity calculation (offline) of GX Works2.
→ Refer to the GX Works2 Version 1 Operating Manual (Common) for details.
• When symbolic information is stored, it is deleted if the memory capacity set by parameters is changed.
After changing the memory capacity, write the symbolic information again.
2.7.4
Compatible optional memory model
1. FX
3S
/FX
3G
 PLCs
*1.
The FX
3S
 Series PLC can hold 16,000 steps of memory, but user program capacity is limited to 4,000 steps.
2. FX
3U
/FX
3UC
 PLCs
*2.
Can be used with FX
3UC
 PLCs Ver. 2.20 or later.
*3.
Ver. 3.00 or later is applicable.
~
 Built-in memory capacity       Can be set by changing parameter
Memory capacity
setting
Unit: Step
Comment capacity 
setting
Unit: Block
File register 
capacity setting
Unit: Block
Special unit initial 
value setting
Unit: Block
Built-in
positioning setting
Unit: Block
Built-in 
CC-Link/LT Setup
Unit: Block
2000
0 to 3
0 to 3
1
4000
0 to 7
0 to 7
1
8000
0 to 15
0 to 14
8
1
16000
0 to 31
0 to 14
8
18
1
32000
0 to 63
0 to 14
8
18
1
64000
~
0 to 127
0 to 14
8
18
1
Model name
Maximum number of 
steps
Memory type
Allowable number of 
times of writing
Remarks
FX
3G
-EEPROM-32L
32000
*1
EEPROM
memory
10000 times
Write-protect switch and loader 
function are provided.
Model name
Maximum number of 
steps
Memory type
Allowable number of 
times of writing
Remarks
FX
3U
-FLROM-64
64000
Flash memory
10000 times
Write-protect switch is provided.
FX
3U
-FLROM-16
*2
16000
Flash memory
10000 times
Write-protect switch is provided.
FX
3U
-FLROM-64L
*2
64000
Flash memory
10000 times
Write-protect switch and loader 
function are provided.
FX
3U
-FLROM-1M
*3
64000
Flash memory
10000 times
Write-protect switch and there is an
area (1300 kB) dedicated to the
storage of symbolic information.