TROUBLESHOOTING
If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and 
the heater may backfi re when lit. If the gas quality or pressure is low, contact your local 
gas supplier immediately. 
W
ARNING
OBSERVED PROBLEM POSSIBLE CAUSE
REMEDY
ODS/pilot lights, but fl ame 
goes out when control knob 
is released.
1.  Control knob not fully pressed in.
1.  Press in control knob fully.
2.  Control knob not pressed in long 
enough.
2.  After ODS/pilot lights, keep control knob 
pressed in for 30 seconds.
3.  Manual shutoff valve not fully open.
3.  Fully open manual shutoff valve.
4.  Thermocouple connection loose at 
control valve.
4.  Hand tighten thermocouple connection 
until snug, then tighten 1/4 turn more.
5. Pilot fl ame not touching thermocouple, 
which allows thermocouple to cool, 
causing pilot fl ame to go out. This 
problem could be caused by either 
low gas pressure, or a dirty or partially 
clogged ODS/pilot.
5.  Contact local gas company.
6. Thermocouple damaged.
6. Replace thermocouple.
7.  Control valve damaged.
7.  Replace control valve.
Burner does not light after 
ODS/pilot is lit.
1. Burner orifi ce is clogged.
1.  Burner orifi ce is clogged.
2. Burner orifi ce diameter is too small.
2.  Burner orifi ce diameter is too small.
3.  Inlet gas pressure is too low.
3.  Inlet gas pressure is too low.
Burner backfires during 
combustion
1.  Manifold pressure is too low.
1.  Contact local gas company.
2. Burner orifi ce is clogged.
2.  Clean burner or replace burner orifi ce.
Slight smoke or odor during 
initial operation.
1. Burner orifi ce is clogged or damaged.
1.  Clean burner or replace burner orifi ce.
2.  Burner is damaged.
2.  Replace burner.
3.  Gas regulator defective.
3.  Replace gas regulator.
Logs appear to smoke after 
initial operation.
1.  Vapors from paint or curing process of 
logs.
1.  Problem will stop after a few hours of 
operation. Run the heater with the damper 
open if you have one, or open a window 
for the fi rst few hours.
2.  Log heater is intended to be smokeless. 
Turn OFF heater and call qualifi ed service 
person.
Heater produces a whistling 
noise when burner is lit.
1.  Turning control knob to HIGH position 
when burner is cold.
1.  Turn control knob to LOW position and let 
warm up for a minute.
2.  Air in gas line.
2.  Operate burner until air is removed from 
line. Have gas line checked by local gas 
company.
3.  Dirty or partially clogged burner orifi ces.
3.  Clean burner or replace burner orifi ce.
No gas to pilot.
1.  LP-regulator shut down due to inlet 
pressure too high.
1.  Verify LP tank regulator is installed and 
set at 11" to 13" w.c.
2.  Replace regulator on heater.