LOCATING YOUR 
GAS FIREPLACE
1)  When selecting a location for your fi replace, 
ensure that the clearances are met as 
outlined in the "Clearances" section.
2)  Provide adequate clearances for servicing.
3)  The appliance must be installed on a fl at, 
solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or raised up 
on a platform to enhance its visual impact. 
If the appliance is going to be installed 
on carpeting, combustible linoleum tile or 
other combustible material other than wood 
fl ooring, the appliance must be installed on a 
metal or wood panel extending the full width 
and depth of the appliance.
4)  The Direct Vent Gas Fireplace can be 
installed as follows:
 
  Model 
 
Position 
 A)  P121-2: 
 
 
See 
Thru
 B)  P131-2: 
 
 
Pier
 C) P121LC-2: 
 
Left 
Corner
 D) P121RC-2: 
 
Right 
Corner
5)  This appliance is Listed for bedroom 
 
installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
6) The P121-2/P121LC-2/P121RC-2/P131-
2 Direct Vent Gas Fireplace is approved 
for alcove installations, which meet the 
clearances listed on this page.
7)  We recommend that you plan your installation 
on paper using exact measurements for 
clearances and floor protection before 
actually installing this appliance. Have a 
qualifi ed inspector, dealer, or installer review 
your plans before installation.
Note:   For Exterior Vent  Termination
 
 
Locations see section "Exterior Vent 
Termination Locations."
INSTALLATION
A) P121-2 See Thru
B) P131-2 Pier
C) P121LC-2 Left Corner
D) P121RC-2 Right Corner