Figure 22.  Gas Supply Line
•  At the gas line access hole, use insulation to re-pack the 
space around the gas pipe.
•  Insert insulation from the outside of the fi replace and pack 
the insulation tightly to totally seal between the pipe and 
the outer casing.
Step 6.  The Gas Supply Line
NOTE: Have the gas supply line installed in accordance 
with local building codes by a qualified installer 
approved and/or licensed as required by the locality. 
(In the Commonwealth of Massachusetts installation 
must be performed by a licensed plumber or gas 
fi tter).
NOTE: Before the fi rst fi ring of the fi replace, the gas 
supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly 
size the gas supply line leading to the 1/2 inch
(13 mm) hook-up at the unit.
This gas fireplace is designed to accept a 1/2 inch 
(13 mm) gas supply line.
To install the gas supply line:
•  A listed (and Commonwealth of Massachusetts ap-
proved) 1/2 inch (13mm) tee-handle manual shut-off 
valve and a listed  fl exible gas connector are connected 
to the 1/2 inch (13mm) inlet of the control valve. NOTE: 
If substituting for these components, please consult local 
codes for compliance.
•  Locate the gas line access hole in the outer casing of 
the fi replace. 
•  The gas line may be run from either side of the fi replace 
provided the hole in the outer wrap does not exceed 2 1/2” 
in diameter and it does not penetrate the actual fi rebox.
•  The gap between the supply piping and gas access 
hole can be plugged with non-combustible insulation to 
prevent cold air infi ltration.
• Open 
the 
fi replace lower grille, insert the gas supply line 
through the gas line hole, and connect it to the shut-off 
valve.
•  When attaching the pipe, support the control so that the 
lines are not bent or torn. 
•  After the gas line installation is complete, use a soap so-
lution to carefully check all gas connections for leaks.
!
Step 7.   Gas Pressure Requirements
Pressure requirements for Heat & Glo gas fi replaces are 
shown in the table below.
USE A WRENCH
ON SHUT-OFF
 VALVE WHEN
TIGHTENING
GAS LINE
MANUAL
SHUT-OFF VALVE
CONTROL
VALVE
GAS LINE
ACCESS
HOLE
GAS
VALVE
FLEX
CONNECTOR
WARNING: DO NOT USE AN OPEN FLAME TO 
CHECK FOR GAS LEAKS
.
A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping is 
provided on the inlet and outlet side of the gas control for 
a test gauge connection to measure the manifold pressure. 
Use a small fl at blade screwdriver to crack open the screw 
in the center of the tap. Position a rubber hose over the tap 
to obtain the pressure reading.
The  fi replace and its individual shut-off valve must be 
disconnected from the gas supply piping system during any 
pressure testing of the system at test pressures in excess 
of one-half (1/2) psig (3.5 kPa).
The fi replace must be isolated from the gas supply piping 
system by closing its individual shut-off valve during any 
pressure testing of the gas supply piping system at test 
pressures equal to or less than one-half (1/2) psig (3.5 
kPa).
Pressure
Natural Gas
Propane
Minimum inlet pressure
5.0 inches
w.c.
11.0 inches
w.c.
Maximum inlet gas 
pressure
14.0 inches
w.c.
14.0 inches
w.c.
Manifold pressure
3.5 inches
w.c.
10.0 inches
w.c.