Hearth & Home Technologies II-B Manuel D’Utilisation

Page de 40
Heat & Glo LifeStyle Collection  •  Twilight-II-B  •  2108-900  Rev. G  •  8/07
17
A.  Recommendation for Wire
This appliance requires 110-120 VAC be wired to the 
junction box for proper operation of the appliance.
Electrical Information 
 
NOTE: This appliance must be electrically wired and grounded 
in accordance with local codes or, in the absence of local 
codes, with National Electric Code ANSI/NFPA 70-latest 
edition 
or the Canadian Electric Code, CSA C221.1.
B.  Connecting to the Appliance
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
•  Incorrect wiring will damage millivolt valves.
•  Incorrect wiring will override IPI safety lockout 
and may cause explosion.
•  This appliance may be used with a wall switch, wall 
mounted thermostat and/or a remote control.
•  If using thermostat use one compatible with a millivolt 
gas valve system.
•  Follow parameters for locating thermostat (see individual 
thermostat instructions) to ensure proper operation of 
appliance.
•  Keep wire lengths short as possible by removing any 
excess wire length.
•  Low voltage and 110 VAC voltage cannot be shared 
within the same wall box.
NOTE: Waterproof insulated wire should be used when wiring 
the junction box.
CAUTION
Label all wires prior to disconnection when servicing controls. 
Wiring errors can cause improper and dangerous operation. 
Verify proper operation after servicing.
Shock hazard.
•  Replace damaged wire with type 105
O
 C 
rated wire.
•  Wire must have high temperature insulation.
CAUTION
WARNING