Hatco 3CS2 Mode D'Emploi

Page de 20
Kilowatts 
Wire Sizing
Fuse or
Model
Voltage
(kW)
Phase
Amps
AWG*
Circuit Breaker*
Shipping Weight
FR2-3
208
3
1
14.5
12
20
24 lbs. (11 kg)
FR2-4
208
4
1
19.2
12
30
24 lbs. (11 kg)
FR2-6
208
6
1
28.8
10
40
27 lbs. (12 kg)
FR2-3
240
3
1
12.5
12
20
24 lbs. (11 kg)
FR2-4
240
4
1
16.7
12
30
24 lbs. (11 kg)
FR2-6
240
6
1
25.0
10
40
27 lbs. (12 kg)
FR2-3B
208
3
3
8.4
14
15
24 lbs. (11 kg)
FR2-4B
208
4
3
11.2
14
15
24 lbs. (11 kg)
FR2-6B
208
6
3
16.7
12
30
27 lbs. (12 kg)
FR2-3B
240
3
3
7.3
14
15
24 lbs. (11 kg)
FR2-4B
240
4
3
9.6
14
15
24 lbs. (11 kg)
FR2-6B
240
6
3
14.5
12
20
27 lbs. (12 kg)
FR2-8
208
8
1
38.4
8
50
27 lbs. (12 kg)
FR2-8
240
8
1
33.3
8
50
27 lbs. (12 kg)
FR2-9B
208
9
3
25.0
10
40
27 lbs. (12 kg)
FR2-9B
240
9
3
21.7
10
30
27 lbs. (12 kg)
FR2-12B
208
12
3
33.4
8
50
27 lbs. (12 kg)
FR2-12B
240
12
3
29.0
10
40
27 lbs. (12 kg)
SPECIFICATIONS
5
ELECTRICAL RATING CHART – FR2 MODELS
* Based upon NEC 2002 Code
† Based upon THHN wire rated 90ºC.
Form No. HHM-1103
NOTE: NSF Standard 4 has recently added performance requirements for food rethermalizing. The requirements mirror 
the requirements for food rethermalizing in the FDA Food Code. The basic requirement is that food reach a temperature 
of 165°F (74°C) in a time period of two hours or less.
Appliances that are manufactured for the purpose of rethermalizing food will need to meet these performance requirements 
in order to be listed to NSF Standard 4.
The Hatco FR2 Series heating unit is specifically made for food rethermalizing, however, the heating unit is designed 
to be incorporated into a hot water bath rethermalizer. Hatco does not supply the vessel that contains the water, nor the system
which determines how food is placed and held in the vessel. The Hatco FR2 unit attaches to the bottom of the vessel and supplies
hot water to the vessel.
Hatco does supply sizing recommendations to enable the appliance manufacturer to correctly size the FR2 unit to the vessel.
However, there are variables in the way that the vessel is manufactured that affect its ability to pass the NSF performance
requirements. The Hatco FR2 unit is listed with NSF for construction only. Due to the fact that the FR2 is only a portion 
of a larger system, it is impossible to do performance testing until the FR2 unit is incorporated onto the water vessel.
The result is that it is the responsibility of the vessel manufacturer to have the entire rethermalizing appliance tested and listed 
in accordance with NSF Standard 4. Simply hanging an NSF listed FR2 unit on the appliance does not transfer NSF listing 
to the entire appliance.