Dansons Group HCF120 Manuel D’Utilisation

Page de 39
 
Copyright 2004                                                                                    
15
                                             
Cheap Charlie
 Owner’s Manual 
Canadian Comfort Industries                                           
www.dansons.com
                                                              Dansons Group Inc. 
A
B
A
C
D
E
F
G
H
J
6”
1”
10”
6”
1”
10”
12”
F
REESTANDING 
I
NSTALLATION
  
. . . continued
 
   
 
 
 
 
 
 
Figure 18 
NOTE: Some horizontal, through the wall installations may require a Clean-Out Tee and a minimum 3’ vertical rise 
of pipe outside the building to help draft the stove.  This is required if a proper burn cannot be maintained, after the 
stove has been tested and the airflow set.  This is due to backpressure in the exhaust, caused by the airflow around 
the house.                          
THROUGH THE WALL -  DIRECT INSTALLATION.   
(Figure 18) 
 
1.  Select the location for your stove, design the exhaust system and determine the brand and size of 
"PL" vent to be used. 
 
2.  Position the floor pad. (C). 
 
3.  INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER 
       Following  the  "PL"  vent  manufacturer's  specifications, mark and cut a hole through the wall to 
accommodate the wall thimble, (A), and the outside air pipe, (B), if outside air is to be used.  
•  Install the wall thimble, (A). Be sure to run a bead of silicone around the outside edges of the 
wall thimble to reduce drafts.  Insert the proper size of "PL" vent, (D), through the wall thimble, 
(A).  
•  Place your stove on the floor pad, (C), close to its final position.  Leave room to connect the 
"PL" vent to your stove.  Place a bead of RTV silicone around the end of your stove's exhaust 
pipe, (E).  Connect the “PL” vent pipe adaptor (J) onto the stoves exhaust pipe.  
•  Connect the length of "PL" vent, (D), that is in the thimble, (A), onto the pipe adaptor (E).  
Fasten together with at least three sheet metal screws (approx. ½” in length). Place a bead of 
RTV silicone around the connection.  
•  Place your stove in its final position on the pad.  Place another bead of RTV silicone around 
the “PL” vent and the inside of the wall thimble, to stop cold air drafts. 
Note:  If 4" PL vent is required, use an increaser, (J), on the stove exhaust pipe. 
 
4.  On the outside of the building, place a 45 degree "PL" type elbow, (F), onto the end of the horizontal 
"PL" vent, (D).  Optionally, place a rodent screen cap, (G), (may be required in some locals), on the 
end of the elbow, (F). Secure all connections using 3 sheet metal screws and run a bead of RTV 
silicone around all connections.  Also run a bead of RTV silicone around the “PL” vent pipe and the 
outside of the wall thimble.  
 
5.  If outside air is used, install the outside air pipe, (B).  Seal the outside air 
pipe, (B), to your    stove's outside air pipe, (I), with RTV silicone.  Make 
sure the outside air pipe fits over, (not inside), your stove's outside air 
pipe.  Install a wind shield (H). Run a bead of silicone around the inside 
and outside walls, again to reduce cold drafts. 
 
 
PL Wall Thimble 
Outside Air Intake  
C Hearth 
Pad 
PL Vent  Length 
E Stove 
Exhaust 
PL 45 deg elbow 
PL Screened End Cap 
Outside Air Intake Screen 
Cap 
Combustion Air Intake 
PL Pipe Adaptor