Mitsubishi PJZ012A087B Manuel D’Utilisation

Page de 22
14
 
ON – TIMER OPERATION
 
< WIRELESS REMOTE 
CONTROL >
Press ON timer button.
ON timer display 
 blinks.
Press 
 or 
 button to adjust to AM 8:00.
Displayed time will be changed by 10 minutes by pressing the buttons.
Press ON timer button.
• ON timer display 
 changes from blinking to steady lighting and 
the setting is completed.
(Press within 60 seconds)
TIMER/CHECK display lamp of the air conditioner is lit. (The receiving part of 
indoor unit)
• At AM 8:00, TIMER/CHECK display lamp turns off and the air conditioner 
will start operating.
1 · 3
2
Operation is started at the setting time.
  In case the ON timer is set while the air 
conditioner is in operation, it will be stopped 
and ready for restart at the setting time.
[EXAMPLE] If you would like to start the operation at AM 8:00
 Cancellation
  Press CANCEL button to turn off the PROGRAM timer 
display and timer is canceled. (Operation condition is kept as 
before the button is pressed.)
  If ON/OFF button is pressed during TIMER operation, 
TIMER display turns off and the TIMER is canceled. The air 
conditioner stops operating.
 Changing the set time
Press OFF TIMER button or ON timer button to set again.
NOTICE 
The same time cannot be set for OFF timer and ON timer.
 
PROGRAM TIMER OPERATION
By setting both ON timer and OFF timer, the settings turn into PROGRAM timer mode. Operation and stopping can be performed at the 
same time of each day by setting program timer once.
Set ON timer.
Press ON timer button and set the time with 
 or 
 button.
Press ON timer button again.
Set OFF timer.
Press OFF timer button and set the time with 
 or 
 button.
Press OFF timer button again.
Both ON TIMER and OFF TIMER are displayed. The direction of arrow mark 
changes depending on the status of operation.
 
 
(stop) (operating)
2
1
 
OFF – TIMER OPERATION
2 · 4
3
1
Operation is stopped at the setting time.
[EXAMPLE] If you would like to stop the operation at PM 9:00 
 Cancellation
  Press CANCEL button to turn off the TIMER display and timer is canceled.
  After TIMER setting, if ON/OFF button is pressed before the setting time, TIMER display turns off and the TIMER is canceled.
 Time  change
Press OFF TIMER button to set again.
 Cancellation 
•  Press CANCEL button to turn off the TIMER display and timer is canceled.
•  After TIMER setting, if ON/OFF button is pressed before the setting time, 
TIMER display turns off and the TIMER is canceled.
 Time  change
Press ON TIMER button to set again.
 
HOW TO OPERATE 
(Dehumidifying operation is prohibited for FDU-F.)
•  Turn on the power supply of both indoor/outdoor units for six hours before starting the unit to protect the units. (The 
crankcase is conducted and the compressor is heated) Do not turn off the power supply. (The crankcase heater is conducted 
while the compressor is stopped, preventing failure of the compressor due to accumulation of liquid refrigerant by keeping the 
compressor warm.)
•  The operation of remote control must be performed slowly and steadily.
HOW TO USE < WIRELESS REMOTE CONTROL >
ATTENTION
4
1
5
3
2
AUTO
COOL
HEAT
DRY
FAN
 Guideline of room temperature setting
COOL ...............26 to 28°C
DRY ..................21 to 24°C
HEAT ................22 to 24°C
FAN ................... TEMP setting is 
unnecessary
•  Operation mode can be changed even 
when the unit stops. 
•  If you operate under the same condition 
(operation mode, set temperature, 
airflow, louver) just follow step 
1
, no 
other operations are necessary. The 
conditions which were set previously are 
indicated on the remote control
 
CURRENT TIME SETTING PROCEDURE
Press TIME SET UP switch.
Press it with the tip of ballpoint etc. The time display blinks and can be set 
to the current time.
Press 
 or 
 
button to adjust to AM 8:00.
Morning : AM After noon : PM
The displayed time changes by 1 minutes when pressing the button.
•  If 
 or 
 button is pressed during the blinking, fast-forward or 
fast-backward can be done.
NOTICE
•  In case the buttons are not pressed for 60 seconds, the displayed time is set as 
current time without step 
3
.
3
 
Press TIME SET UP switch.
The display changes from blinking to steady lighting and the setting is 
completed. 
1 · 3
2
The timer is set on the current time. Adjust the current time correctly at first of all.
 [EXAMPLE] AM (morning) 8:00 setting
OPERATION
Press 
 button.
The operation display light (Green) turns on, and the operation starts.
The setting status is displayed on the liquid crystal area on the remote 
control.
Press MODE button.
Current operation mode is indicated with the 
 marks besides the 
operation mode icons.
The mode will change in the following order by pressing the button.
(AUTO)*        COOL        HEAT
             FAN         DRY 
(The automatic operation can be selected in case of heat recovery system 
KXR only. In case of KX, the automatic operation cannot be selected. In this 
case, setting changes it to automatic operation.) 
 See page 13
Press TEMP  button.
Set the room temperature by pressing 
 or 
 button.*
*  IN case of FDU-F
The setting temperature of the remote controller indicates the outdoor 
temperature while operating thermostat ON/OFF.
Press FAN SPEED button.
→ HI → MED → LO— FAN SPEED can be changed in order.
Press AIR FLOW button.
Effective AIR FLOW direction 
 see page 15
AUTO mode operation ............. Intermediate
Cooling, dehumidifying mode ... Horizontal
Heating mode .......................... Downwards
Stop
 Press 
 button
Operation mode
Press ON/OFF button when the air conditioner stops.
The air conditioner starts to operate.
OFF timer can be set only in case the air conditioner is in operation.
Press OFF timer button.
OFF timer display 
 blinks.
Press 
 or 
 button to adjust to PM 9:00.
Displayed time will be changed by 10 minutes by pressing the buttons.
Press OFF timer button.
• OFF timer display 
 changes from blinking to steady lighting and 
the setting is completed. (Press within 60 seconds)
TIMER/CHECK display lamp of the air conditioner is lit. (The receiving part 
of indoor unit)
• At PM 9:00, TIMER/CHECK display lamp turns off and the air 
conditioner 
will stops operating.
PJZ012A087B.indd   14
PJZ012A087B.indd   14
2014-3-4   10:28:41
2014-3-4   10:28:41