Raypak 2100-4001 Fascicule

Page de 2
Catalog No.:  2000.26M 
Effective:  12-1-07 
Replaces:  12-1-99
 
Job: 
 
           
 
 
Engineer: 
 
           
 
Contractor: 
 
           
 
Prepared By: 
            
 
 
Model
:   
           
 Date: 
            
 
 
 
EFFICIENT 
 82% thermal efficiency – highest of any atmospheric 
boiler available today 
THERMAL SHOCK PROOF 
 Twenty-year warranty against thermal shock damage 
up to 150°F differential 
 Maximum operating temperature: 230°F 
LIGHTWEIGHT 
 A floor load of 70 lbs./sq. ft. or less 
HIGH RECOVERY 
 Cuts fuel costs substantially because the standby and 
radiation losses normal to other boilers and tank-type 
water heaters are eliminated 
LOW WATER OPERATING TEMPERATURE 
 Operates with water temperature as low as 105°F 
without condensing 
 
Heat Exchanger 
ƒ  ASME Inspected and Stamped 
160 PSIG 
ƒ  National Board Approved 
ƒ Headers 
 Glass-lined Cast Iron – Standard  
 Bronze – Option A-1 
ƒ Finned 
Tubing 
 Copper – Standard  
 Cupro Nickel – Option A-3 
ƒ  ASME Steel Tube Sheet 
ƒ Silicone 
O-Rings 
ƒ  60 PSIG ASME Pressure Relief Valve 
ƒ  Temperature and Pressure Gauge 
(Boiler) 
ƒ Water 
Connections 
 Left Hand – Standard  
 Right Hand – Option A-6 
ƒ Flow 
Configuration 
 Two-pass (Standard) 
 Single-pass (Cast Iron Only) 
Controls 
ƒ  120V, 60Hz, 1 Ph Power Supply 
ƒ 120/24V 
Transformer 
ƒ  100% Pilot Shut-off/Lockout 
ƒ  Electronic, Intermittent Ignition (IID) 
Pilot 
ƒ  High Limit Control, Manual Reset 
ƒ  High Limit Control, Auto Reset – 
Models 3001-4001 
ƒ On/Off 
Switch 
ƒ Flow 
Switch 
ƒ  Economaster II Pump Time Delay 
Gas Control Train 
ƒ  Manual Main Gas Shut-off Cock 
ƒ  Main Gas Pressure Regulator 
ƒ  Redundant Safety Shut-off Valve 
ƒ  Control Valve         
ƒ Firing 
Mode 
 On/off (H4) 
 Two-stage Firing (H3) 
 Four-stage Firing (H9) 
 Motorized Modulation (H2) 
 B-6000 (H6) 
ƒ Fuel 
 Natural Gas 
 Propane Gas     
ƒ  Design Certified ANSI Z21.13/ 
CSA 4.9 
Construction 
ƒ Front 
Controls 
ƒ  Stainless Steel Burners 
ƒ  Polytuf Powder Coat Finish 
ƒ  Built-in Draft Diverter 
ƒ Draft 
Inducer 
 Motorized Draft Inducer –  
Option D-2 
 
 
Temperature Controllers 
 B-7 
Modulating 
 B-5 
Modulating, Outdoor Reset 
 B-6 
Two-stage 
 B-    Four-stage Digital 
 Y-241 Electronic Sequencer,  
1-4 Stages 
 
 Y-281 Electronic Sequencer,  
1-8 Stages 
Additional Safety Controls 
 F-9 
Low Water Cut-off Probe 
 I-1 
High Limit Control,  
Auto Reset 
 S-1 
Low Gas Pressure Switch 
 S-2 
High Gas Pressure Switch 
                       
 
                       
 
Regulatory Agency Requirements 
            
 
            
 
Raytherm
®
 
- Type H
Hydronic Heating Boilers
Commercial
Models 2100-4001 (Indoor)
Fig. 8184