H
Symptom
Standby Button State
Possible Cause
Action
Desired input source 
cannot be detected
The input source is not 
active. A signal must be 
present for the input to be 
selected.
Connect an active input 
source to unit.
The input device (e.g. 
computer, DVD player, 
etc.) is not turned on.
Turn on input source.
The remote control does 
not work
The remote control is not 
facing the remote control 
sensor.
Face the remote control 
toward the remote control 
sensor.
The remote control is too 
far from the sensor
Operate the remote 
control within 5 meters.
An obstruction is between 
the remote control and the 
sensor.
Remove obstacle.
The remote control’s 
batteries are exhausted or 
inserted wrong.
Correctly insert batteries.
Projector Indicator Lights
Mode
Indicator Signal on Projector
Stand by
Orange LED (always ON)
Lamp Strike
Orange LED (Flashing)
Normal Operations
Green LED (always ON)
Fan Error
Red LED (One flash every second)     (
• • •
)
Thermal Error
Red LED (Two flashes every second) (     
•• •• ••
      )
Communication Error
Red LED (Four flashes every second) (     
•••• •••• ••••
      )
Cooling (Lock Out)
Red LED (Solid light)
I/O Module Indicator Lights
Mode 
Indicator Signals on I/O Model Box
Stand by
Orange LED (always ON)
Normal Operations
Green LED (always ON)
Cooling (Lock Out)
Red LED (Solid light)