STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If 
unsure about household wiring procedures, call your local heat-
ing/air-conditioning contractor.
Refer to the labels you placed on the wires when you removed the old 
thermostat (see illustration).
Match the letter of your old thermostat wire with the corresponding 
terminal letter on your new thermostat. Refer to Table 2.
Remove the factory-installed jumper connecting terminals R and RC if 
wires are connected to both of those terminals.
For wiring diagrams, if needed, see pp 21-22.
Loosen the terminal screws. Slip each wire beneath its matching 
terminal. Wraparound and straight connections are both acceptable, 
(see illustration). Tighten the terminals.
Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation.
M16425
R
W
Y
G
M4826
FOR WRAPAROUND 
INSERTION STRIP 
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION 
STRIP 5/16 IN. (8 MM).