Changing the Orientation of the Fluid Inlet 
and Outlet Ports
The pump is shipped with the ports facing the same 
direction. To re-orientate the ports into any position:
1.
Remove the clamps (130) holding the inlet and/or 
outlet tee to the elbows.
2.
Rotate the manifold tee (339) and reattach. Install 
the clamps (130) and tighten handtight.
Air Exhaust Ventilation
The air exhaust port is 3/4 npt(f). Do not restrict the air 
exhaust port. Excessive exhaust restriction can cause 
erratic pump operation. 
To provide a remote exhaust:
1.
Remove the muffler (P) from the pump air exhaust 
port. See F
2.
Install a grounded air exhaust hose (T) and connect 
the muffler (P) to the other end of the hose. The 
minimum size for the air exhaust hose is 3/4 in. (19 
mm) ID. If a hose longer than 15 ft (4.57 m) is 
required, use a larger diameter hose. Avoid sharp 
bends or kinks in the hose.
3.
Place a grounded container (U) at the end of the air 
exhaust line to catch fluid in case of a diaphragm 
rupture. See F
F
IG
. 4 Orientation of Fluid Ports
130
339
TI5133e
P
Be sure the system is properly ventilated for your type 
of installation. You must vent the exhaust to a safe 
place, away from people, animals, food handling 
areas, and all sources of ignition when pumping flam-
mable or hazardous fluids.
Diaphragm failure can cause the fluid being pumped 
to exhaust with the air. Place an appropriate con-
tainer at the end of the air exhaust line to catch the 
fluid. See F