Argosy Research H-125 Series Manuel D’Utilisation

Page de 40
33
h125 speCifiCaTiOns
H125
H125
H125
H125
H125
H125
H125
Model #
32-10
48
64
96
128
160
192
Factory Regeneration 
Settings
Backwash      Minutes
8
8
8
8
8
8
8
                     Gallons
18
18
34
34
42
60
60
Brine/Rinse    Minutes
60
60
68
68
68
68
68
                     Gallons
19.2
22.2
43.5
47.7
71.1
89.1
113
Backwash      Minutes
8
8
8
8
8
8
8
                     Gallons
18
18
34
34
42
60
60
Fast Rinse     Minutes
4
4
4
4
4
4
4
                     Gallons
9
9
17
17
21
30
30
Fill                Minutes
6:32
9:53
13:14
19:56
26:38
33:20
40:02
                     Gallons
3.2
4.7
6.5
9.8
13.2
16.6
20
Total  Regeneration Gallons*
66
71
134
142
190
256
283
Refill LBS of salt
Lbs.
Lbs.
Lbs.
Lbs.
Lbs.
Lbs.
Lbs.
Low Salt
6
9
12
18
24
30
36
Medium Salt
10
15
20
30
40
50
60
High Salt
15
22.5
30
45
60
75
90
Capacity
Grains
Grains
Grains
Grains
Grains
Grains
Grains
Low Salt
19,000
28,500
38,000
57,000
76,000
95,000
114,000
Medium Salt
28,000
42,000
56,000
84,000
112,000
140,000
168,000
High Salt
32,000
48,000
64,000
96,000
128,000
160,000
192,000
Service Flow Rates  
GPM
GPM
GPM
GPM
GPM
GPM
GPM
Continuous @ 15 psi
22
19
25
24
25
27
26
Peak @ 25 psi
31
28
34
33
34
35
34
Flint Under bed (lbs.)
14
14
40
40
45
50
75
High Capacity Resin (cu.ft.)
1
1.5
2
3
4
5
6
Resin Tank Size
10x44
10x54
13x54
14x65
16x65
18x65
18x65
Recommended Brine Tank
18x40
18x40
18x40
18x40
24x41
24x50
24x50
Brine Line Size
3/8”
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
DLFC (gpm)
2.2
2.2
4.2
4.2
5.3
7.5
7.5
BLFC (gpm)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
Injector Size
D-Red
E-White
G-Yellow
H-Green
I-Orange
J- Lt. Blue
K- Lt. Green
Injector Draw Rate @ 50 psi
0.22
0.27
0.46
0.46
0.6
0.7
0.7
Injector Slow Rinse @ 50 psi
0.32
0.37
0.64
0.71
1.1
1.4
1.8
H125 Specifications
* Calculations are based on factory medium salt setting @ 50 psi
 73-363
\\file02\users$\bkoenig\Marketing\Web site\Specs\73-363H125SPECSHEETUPDATED120307.xls
Updated 12-03-2007
LBRY