Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-744
E-DIG-BD (Multi Application Platform Board) 
9
Hyperactivity
The common circuit pack is considered “hyperactive” if the service dispatcher 
receives 200 up-link messages from the circuit pack in a 10-second period. 
Since MAPD has 32 ports, the hyperactivity limit is increased to 500 up-link 
messages per 10seconds. An alarm is issued and the board taken out of service 
when the limit reaches 400 or when it hits 500 up-link messages in 10 seconds.
LED Use
The LED Control message 038x requests the Angel to drive the Red, Yellow, and 
Green LEDs on the face plate of typical port board on or off. On the MAPD, only 
the Red LED is controlled by this message. Yellow and Green change requests 
received from the switch by the MAPD drive LCD behavior rather than LED 
behavior. The switch continues to send the same LED control messages to the 
MAPD that it currently sends to all other port boards. The MAPD handles proper 
interpretation of these messages. You should note that the PC on the MAPD, as 
well as the switch itself, can control the LEDs and the LCD on the MAPD.
Port Administration
In administration without hardware, the switch allows administration of up to 32 
MAPD ports of any port type. If the port type later reported by the board does not 
match the existing type, the switch assumes the board is a MAPD board with a 
different configuration and rejects the board. MAPD_DCP_STA and MAPD_ASAI_
STA are the only two types of terminals are allowed on a MAPD board. Therefore, 
while administering ports on MAPD using add station form, it will allow only the 
terminals mentioned above.
NOTE:
Refer to XXX-BD (Common Port Circuit Pack) maintenance documentation 
for circuit pack level errors. See also DIG-LINE maintenance 
documentation for related line information.