Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1084
MODEM-PT (Modem Pool Port) 
9
Error Log Entries and Test to Clear Values
Table 9-430.
Modem Pool Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
18
0
busyout UUCSS
WARNING
OFF
release port UUCSS
130
2
2.
This error type indicates that the circuit pack has been removed or has been insane for more than 21 
minutes. To clear the error, reinsert or replace the circuit pack.
None
WARNING
ON
test port UUCSSpp sh
257
Conversion Resource Loop 
(#98)
MINOR
ON
test port UUCSS s r 3
513
Modem Conference (#97)
MINOR
ON
test port UUCSS l r 3
769
Modem NPE Crosstalk (#96)
MINOR
ON
test port UUCSS l r 3