Lucent Technologies Release 6 Manuel D’Utilisation

Page de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-63
Multi-point Adapters 
5
Basic Multipoint Installation Distances
Figure 5-28
 provides cabling information for fan-out of ISDN-BRI multi-point 
installations. The terminating resistor is generally located in the satellite closet. All 
distances assume 24 AWG (#5) (0.26 mm
2
) D-Inside Wire (DIW).
Figure 5-28.
Basic Multi-point with 1 Work Location
Figure Notes
1. S-Interface Source (TN556)
2. Terminating Resistor
3. Satellite Closet
4. Maximum Distance from S-Interface 
Source to Work Location (1600 Feet) 
(488 m)
5. Maximum Distance From Satellite 
Closet to Work Location (250 Feet) 
(76 m)
6. System Cabinet
7. Terminating Endpoint 1
8. Terminating Endpoint 2
9. Work Location
10. Maximum Distance from 
Information Outlet to Terminating 
Endpoint (33 Feet) (10 m)
11. Information Outlet (Bridged Tap)
2
3
8
9
7
1
10
11
11
5
4
6
inst_dis CJL 030796