Lucent Technologies Release 6 Manuel D’Utilisation

Page de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-111
Add ISDN — PRI 
5
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
RETURN
 to verify that the system is in the “active/standby” mode.
2. Enter save translation and press 
Enter
. This instructs the system to take all 
translation information in memory and write it to the translation card or 
tape.
3. If the system contains a TN750/B Announcement circuit pack, enter 
display announcements and press 
Enter
. If administered recorded 
announcements are listed, enter list configuration software- version 
press 
Enter
. Check Page 2 of this form to see when the announcements 
were last saved. To save the announcements, enter save 
announcements
 and press 
Enter
.
Power Down System
1. At the PPN, set the main circuit breaker to OFF.
2. At an EPN, set the main circuit breaker to OFF.
Add Circuit Packs
1. Determine port assignment of circuit packs to be added.
2. Install the TN767C DS1 or TN464C DS1/E1 Interface circuit pack in 
assigned carrier slot.
3. Remove an existing TN756 Tone Detector/Generator circuit pack and 
install the TN768, TN780, TN2182, or TN419B Tone-Clock circuit pack in 
assigned carrier slots, if required.
4. Install a TN765 Processor Interface circuit pack if required and a TN748B 
(or the non-United States TN420B) Tone Detector circuit pack if required.
Install Cables
Install cables from cabinet to cross-connect field as required.
Power Up System
1. At an EPN, set the main circuit breaker to ON.
2. At the PPN, set the main circuit breaker to ON.
3. The system performs a level 4 reboot, loading the system translations from 
the translation card or the tape. Rebooting takes 8 to 20 minutes.
4. After all trouble is cleared, verify the EMERGENCY TRANSFER CONTROL 
switch is set to AUTO. This restores the system to the normal mode.