Hitachi HTS541616J9SA00 Manuel D’Utilisation

Page de 167
Travelstar 5K160 (SATA) Hard Disk Drive Specification 
 
161/167 
15    Timings  
The timing of BSY and DRQ in Status Register are shown in “Timeout Values” on Page 5.  
The other timings are described in “Part1 Functional Specification” section  
FUNCTION INTERVAL 
START 
STOP TIMEOUT
Power On and 
COMRESET 
Device Ready 
After Power On 
Power On and COMRESET 
Status Register 
BSY=0 and RDY=1 
and sends a Register 
FIS to the host. 
31 sec 
Device Busy 
After Software Reset 
Device Control Register 
RST=1 and sends a Register 
FIS to the Device. 
Status Register 
BSY=1 
400 ns 
Software 
Reset 
Device Ready 
After Software Reset 
Device Control Register 
RST=0 and sends a Register 
FIS to the Device.    After 
RST=1 and sends a Register 
FIS to the Device.   
Status Register 
BSY=0 and RDY=1 
and requests to send a 
Register FIS to the host. 
31 sec 
COMRESET Device 
Ready 
After COMRESET 
COMRESET Signal 
Asserted 
Status Register 
BSY=0 and RDY=1 
and sends a Register 
FIS to the Host. 
31 sec 
Device Busy 
After a Register FIS to issue a 
command 
Sets proper values in the 
registers and sends a Register 
FIS 
Status Register 
BSY=1 
400 ns 
PIO SETUP FIS for data-in 
transfer 
Status Register 
BSY=1 
Status Register 
BSY=0 and DRQ=1 
and sends a PIO 
SETUP FIS to the host. 
30 sec 
Data In 
Command 
Device Busy 
After Data Transfer In 
A PIO SETUP FIS is 
transferred to the host. 
Status Register 
BSY=1 
10 us 
Device Busy 
After a Register FIS to issue a 
command 
Sets proper values in the 
registers and sends a Register 
FIS 
Status Register 
BSY=1 
400 ns 
Device Busy 
After Data Transfer Out 
Sends a Data FIS to the device. Status Register 
BSY=1 
5 us 
Data Out 
Command 
PIO SETUP FIS for data-out 
transfer 
Status Register 
BSY=1 
Status Register 
BSY=0 and RDY=1 
and sends a PIO 
SETUP FIS to the host. 
30 sec 
(Note.1) 
Device Busy 
After a Register FIS to issue a 
command 
Sets proper values in the 
registers and sends a Register 
FIS 
Status Register 
BSY=1 
400 ns 
Non-Data 
Command 
A Register FIS to report 
Command Complete 
Status Register BSY=1 
Sets the status of the 
command to the Status 
Register and sends a 
Register FIS to the host 
30 sec 
(Note.2) 
DMA Data 
Transfer 
Command 
Device Busy 
After a Register FIS to issue a 
command 
Sets proper values in the 
registers and sends a Register 
FIS 
Status Register 
BSY=1 
400 ns 
Figure 110 Timeout Values   
Command category is referred to “6.0 Command Protocol” on Page 5.  
The abbreviations “ns”, “us”, “ms” and “sec” mean nanoseconds, microseconds, milliseconds and 
seconds, respectively.  
We recommend that the host system executes Soft reset and then retry to issue the command if 
the host system timeout would occur for the device.