Travelstar 5K160 (SATA) Hard Disk Drive Specification 
 
48/167 
12   General Operation Descriptions   
12.1  Reset Response   
There are three types of reset in ATA as follows:   
Power On Reset (POR) 
The device executes a series of electrical circuitry diagnostics, spins up the HDA, 
tests speed and other mechanical parametric, and sets default values. 
COMRESET 
COMRESET is issued in Serial ATA bus. 
The device resets the interface circuitry as well as Soft Reset. 
Soft Reset (Software Reset) 
SRST bit in the Device Control Register is set, then is reset. 
The device resets the interface circuitry according to the Set Features requirement.
The actions of each reset are shown in “Reset Response Table” on 
Page 5
   
  
POR 
COMRESET 
Soft Reset 
Aborting Host interface   
Aborting Device operation 
(*1) 
(*1) 
Initialization of hardware 
Internal diagnostic 
Starting spindle motor 
(*5) 
Initialization of registers (*2) 
Reverting programmed parameters to default 
(*6) 
(*3) 
    - Number of CHS (set by Initialize Device Parameter) 
 
 
 
  - Multiple mode 
 
 
 
  - Write cache 
 
 
 
  - Read look-ahead 
 
 
 
    - ECC bytes 
 
 
 
    - Volatile max address 
 
 
 
Power mode 
(*5) 
(*4) 
(*4) 
Reset Standby timer value 
 
O ---- execute 
X ---- not execute 
Note. 
(*1)  Execute after the data in write cache has been written. 
(*2)  Default value on POR is shown in “Default Register Values” on 
Page 5
(*3)  The Set Features command with Feature register = CCh enables the device to 
revert these parameters to the power on defaults. 
(*4)  In the case of sleep mode, the device goes to standby mode. In other case, 
the device does not change current mode. 
(*5)  According to the initial power mode selection. 
(*6)  See 5.15 Software Setting Preservation feature. 
Figure 5 Reset Response Table   
12.1.1 
Register Initialization   
After power on, COMRESET, or software reset, the register values are initialized as shown in the following table.   
Register Default 
Value 
Error Diagnostic 
Code 
Sector Count 
01h 
LBA Low 
01h 
LBA Mid 
00h 
LBA High 
00h 
Device 00h 
Status 50h