Hitachi HTS541616J9SA00 Manuel D’Utilisation

Page de 167
Travelstar 5K160 (SATA) Hard Disk Drive Specification 
 
91/167 
 
14.9  Idle (E3h/97h)   
Command Block Output Registers 
  Command Block Input Registers 
Register 
7 6 5 4 3 2 1 0   Register 
7 6 5 4 3 2 1 0
Data 
- - - -
-
-
-
-  Data 
- - - - - -
-
-
Feature - 
-
-
-
-
-  
Error 
...See 
Below... 
Sector 
Count 
V V V V V V V V  Sector 
Count 
- - - - - -
-
-
LBA 
Low 
- - - -
-
-
-
-  LBA 
Low 
- - - - - -
-
-
LBA 
Mid 
- - - -
-
-
-
-  LBA 
Mid 
- - - - - -
-
-
LBA High 
-  -  -  -
-
-
-
-   LBA 
High 
- - - - - -
-
-
Device 
- -
-
-
-
-  Device 
- - - - - -
-
-
Command 
1 1 1 0 0 0 1 1   Status 
...See 
Below... 
 
Error Register 
 
Status Register 
7 6 5 4 3 2 1 0 
 7 6 5 4 3 2 1 0 
CRC UNC  0 
IDN 
0  ABT  T0N
AM
 BSY RDY
DF DSC DRQ 
COR IDX
ERR
0 0 0  0  0 V 0  0 
 0 V 0 V  -  0  0 V 
Figure 42 Idle Command (E3h/97h)   
When the power save mode is Standby mode, the Idle command causes the device to enter 
performance Idle mode immediately, and set auto power down timeout parameter(standby timer). 
And then the timer starts counting down. When the device’s power save mode is already any idle 
mode, the device keep that mode.   
When the Idle mode is entered, the device is spun up to operating speed. If the device is already 
spinning, the spin up sequence is not executed.   
During Idle mode the device is spinning and ready to respond to host commands immediately.   
Output Parameters To The Device 
Sector Count 
Timeout Parameter. If zero, the timeout interval(Standby Timer) is    disabled. If other than 
zero, the timeout interval is set for (Timeout Parameter x5) seconds. 
The device will enter Standby mode automatically if the timeout interval expires with no 
device access from the host. The timeout interval will be reinitialized if there is a device 
access before the timeout interval expires.