Hitachi HDS721025CLA382 Manuel D’Utilisation

Page de 258
Hitachi hard disk drive specifications   
200 
11.39  Set Max Address Ext (37h) 
 
Command Block Output Registers
 
 
Command Block Input Registers
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
Data Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Data High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Feature
 
Current
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Error
 
…See Below…
 
Previous
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
   
 
Sector Count
 
Current
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
B
 
 
Sector Count
 
HOB=0
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Previous
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
HOB=1
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Sector 
Number
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Sector 
Number
 
HOB=0
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Cylinder Low
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Cylinder Low
 
HOB=0
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Cylinder High
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Cylinder High
 
HOB=0
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Device/Head
 
-
 
1
 
-
 
D
 
-
 
-
 
-
 
-
 
 
Device/Head
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Command
 
0
 
0
 
1
 
1
 
0
 
1
 
1
 
1
 
 
Status
 
…See Below…
 
 
Error Register
 
 
Status Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
CRC
 
UNC
 
0
 
IDN
 
0
 
ABT
 
T0N
 
AMN
 
 
BSY
 
RDY
 
DF
 
DSC
 
DRQ
 
COR
 
IDX
 
ERR
 
0
 
0
 
0
 
0
 
0
 
V
 
0
 
0
 
 
0
 
V
 
0
 
-
 
-
 
0
 
-
 
V
 
Table 146    Set Max Address Ext Command (37h) 
 
This command is immediately preceded by a Read Native Max Address Ext command.   
This command overwrites the maximum number of Address of HDD in a range of actual device capacity. Once 
device receives this command, all accesses beyond that Address are rejected with setting ABORT bit in status 
register.   
When  the  address  requested  is  greater  than  268,435,455,  words  (103:100)  shall  be  modified  to  reflect  the 
requested value, but words (61:60) shall not be modified. When the address requested is equal to or less than 
268,435,455, words (103:100) shall be modified to reflect the requested value, and words (61:60) shall also be 
modified. 
If  this  command  is  not  supported,  the  maximum  value  to  be  set  exceeds  the  capacity  of  the  device,  a  host 
protected  area  has  been  established  by  a  Set  Max  Address  command,  the  command  is  not  immediately 
preceded  by  a  Read  Native  Max  Address  Ext  command,  or  the  device  is  in  the  Set  Max  Locked  or  Set  Max 
Frozen state, the device shall return command aborted. 
The device returns the command aborted for a second non-volatile Set Max Address Ext command until next 
power on or hardware reset.