Hitachi HDS721025CLA382 Manuel D’Utilisation

Page de 258
Hitachi hard disk drive specifications   
254 
12 
Timings
 
The timing of BSY and DRQ in Status Register are shown in Table 180Table 181. 
The other timings are described in HDS7210xxCLA3yz / HUA7220xxCLA33z / HCS5C10xxCLA382 / 
HCS7210xxCLA3y2 
HDS5C10xxCLA382 Final Functional Specification. 
FUNCTION
 
INTERVAL
 
START
 
STOP
 
TIMEOUT
 
Power On 
and 
COMRESET
 
Device Busy after Power On
 
Power On
 
The device sets BSY(=0) and 
RDY(=1) to the Status 
Register and sends a Register 
FIS to the host.
 
31 sec
 
Software 
Reset
 
Device Busy after Software 
Reset
 
The host asserts SRST(=1) 
in the Device Control 
Register and sends a 
Register FIS to the Device.
 
The Host sets BSY(=1) to the 
Status Register.
 
400 ns
 
Device Ready after 
Software Reset
 
The host asserts SRST(=1) 
to the Device Control 
Register and sends a 
Register FIS to the Device. 
Then the host negates 
SRST(=0) to the Device 
Control Register and sends a 
Register FIS to the Device.
 
The device sets BSY(=0) and 
RDY(=1) to the Status 
Register and requests to send 
a Register FIS to the host.
 
31 sec
 
COMRESET
 
Device 
Ready 
after 
COMRESET
 
COMRESET Signal asserted
 
The  device  sets  BSY(=0)  and 
RDY(=1) 
to 
the 
Status 
Register and sends a Register 
FIS to the Host.
 
31 sec
 
Non-Data 
command
 
Device Busy after a Register 
FIS to issue a command
 
The host sets proper values 
in the registers and sends a 
Register FIS
 
The host sets BSY(=1) to the 
Status register
 
400 ns
 
A Register FIS to report 
Command Complete
 
The host sets BSY(=1) to the 
Status Register
 
The device sets the status of 
the command to the Status 
Register and sends a Register 
FIS to the host
 
30 sec
 
PIO Data In 
command
 
Device Busy after a Register 
FIS to issue a command
 
The host sets proper values 
in the registers and sends a 
Register FIS
 
The host sets BSY(=1) to the 
Status Register
 
400 ns
 
PIO SETUP FIS for data-in 
transfer
 
The host sets BSY(=1) to the 
Status Register
 
The device sets BSY(=0) and 
DRQ(=1) to the Status 
Register and sends a PIO 
SETUP FIS to the host.
 
30 sec
 
Device Busy after data-in 
transfer
 
A PIO SETUP FIS is 
transferred to the host.
 
The host sets BSY(=1) to the 
Status Register
 
400 ns
 
PIO Data 
Out 
Command
 
Device Busy after a Register 
FIS to issue a command
 
The host sets proper values 
in the registers and sends a 
Register FIS
 
The host sets BSY(=1) to the 
Status Register
 
400 ns
 
Device Busy after data-out 
transfer 
The host sends a Data FIS to 
the device.
 
The host sets BSY(=1) to the 
Status Register 
400 ns
 
PIO SETUP FIS for data-out 
transfer
 
The host sets BSY(=1) to the 
Status Register
 
The device sets BSY(=0) and 
DRQ(=1) to the Status 
Register and sends a PIO 
SETUP FIS to the host.
 
30 sec
 
Table 180    Timeout Values