Fujitsu MBB2147RC Manuel D’Utilisation

Page de 98
Specifications 
2.1.3 Environmental 
specifications 
 
Table 2.3 lists environmental and power requirements. 
 
Table 2.3 
Environmental/Power requirements 
Specification 
Item 
MBB2147RC MBB2073RC 
Operating 
5 to 55 °C 
Non-operating 
–40 to 70 °C 
Transport  
–40 to 70 °C 
DE surface temperature at operating
5 to 60 °C 
Temperature 
(*1) 
Gradient 
20 °C/h or less 
Operating 
5 to 95 %RH 
Non operating 
5 to 95 %RH 
Transport  
5 to 95 %RH 
Relative 
humidity 
Maximum wet bulb temperature 
29 °C (no condensation) 
Operating (*3) 
0.6 mm (5 to 20Hz) / 9.8 m/s
2
 (1G) (20 to 300Hz) or less 
Non-operating (*4) 
3.1 mm (5 to 20Hz) / 49m/s
2
 (5G) (20 to 300Hz) or less 
Vibration 
(*2) 
Transport (packaged) 
3.1 mm (5 to 20Hz) / 49m/s
2
 (5G) (20 to 300Hz) or less 
Operating 980 
m/s
2
 (100G) / 1 ms duration 
Non-operating 3,920 
m/s
2
 (400G) / 1 ms duration 
Shock (*2) 
Transport (packaged) 
3,920 m/s
2
 (400G) / 1 ms duration 
Operating 
–305 to +3,048 m (–1,000 to +10,000 feet) 
Altitude 
Non-operating 
–305 to +12,192 m (–1,000 to +40,000 feet) 
Regulation ±5% 
Ready (average) 
0.18A 
0.16A 
Spin up 
1.2A (peak) 
1.5A (less than 100µs) 
Peak operating current 
Maximum (peak) DC 
(*6) 
1.2A 
+12V DC 
Peak operating current 
DC (reference) (*6) 
0.38A 0.36A 
Regulation ±5% 
Ready (average) 
0.5A 
Peak operating current 
Maximum (peak) DC 
(*6) 
1.2A 
+5V DC 
Peak operating current 
DC (reference) (*6) 
0.78A 
Power 
requirement 
(*5) 
Ripple (+5V, +12V) 
250mVp-p or less (*7) 
 
 
24 