Avery 6057 Manuel D’Utilisation

Page de 60
 
Configuring I 2 of 5 Bar Codes 
1. 
To configure I 2of5 settings, select I 2 of 5 from the Scanner 
Configuration window.   
I 2of5 
Allows the scanner to scan I 2of5 bar codes. 
Transmit 
CD 
Tells the scanner to return the check digit with the data 
when an I 2of5 bar code is scanned. 
Convert 
to 
EAN13 
Tells the scanner to convert 14-character I 2of5 bar 
codes into an EAN13 bar code. 
 
For the conversion to work, the following must occur: 
  I 2of5 bar codes must be enabled. 
  14 must be a valid length. 
  The data must have a leading zero. 
  The data must include an EAN13 check digit. 
Verify 
CD 
Tells the scanner to check the integrity of a scanned  
I 2of5 bar code to ensure it complies with either USS or 
OPCC standards. 
Lengths
  
Sets the 
length(s) 
for I2 of 
5 bar 
codes.   
Variable, 
specifies that I 2of5 bar codes can be any length. 
Note:
 Specifying a range of lengths increases the likelihood of unsuccessful scans. 
1 Fixed, 
specifies a single length for valid I 2of5 bar codes.  The range for Length 1 is 
2 – 99
.  The default is 14. 
2 Fixed, 
specifies two lengths for valid I 2of5 bar codes.  The range for Length 2 is  
2 – 99
.  The default is 0. 
2. 
Enable each bar code you need to scan.   
3. 
Touch OK to save all the settings and return to the Scanner Configuration window. 
 Configuring MSI Bar Codes 
1. 
To configure MSI settings, select MSI from the Scanner 
Configuration window.   
MSI 
Allows the scanner to scan MSI bar codes. 
Transmit CD 
Tells the scanner to return the check digit with the data 
when an MSI bar code is scanned. 
Mod 10/11 
CD Scheme 
Tells which algorithm to use to ensure the integrity of a 
two-check digit MSI bar code. 
Use 2 CDs 
Tells the number of check digits that MSI bar codes 
should have. 
Note:
 Check digits are not always returned with the 
data.  If you choose two check digits, you must 
choose a check digit algorithm. 
Lengths
  
Sets the 
length(s) for 
MSI bar 
codes.   
Variable, 
specifies that MSI bar codes can be any 
length. 
Note:
 Specifying a range of lengths increases the 
likelihood of unsuccessful scans. 
 
 
1 Fixed, 
specifies a single length for valid MSI bar codes.  The range for Length 1 is  
1 – 99
.  The default is 6. 
2 Fixed, 
specifies two lengths for valid MSI bar codes.  The range for Length 2 is  
1 – 99
.  The default is 55. 
2. 
Enable each bar code you need to scan. 
3. 
Touch OK to save all the settings and return to the Scanner Configuration window. 
Configuring the Scanner  7-7