RAD Data comm ASM-60 Manuel D’Utilisation

Page de 74
Chapter 1  Introduction 
ASM-60 Installation and Operation Manual 
1-2 Overview
 
 
Table 1-1.  Typical ASM-60 Ranges 
Data Rate  
24 AWG 
(Mbps) km miles 
4.096 2.0 
1.2 
6.144  
2.0 
1.2 
10.24  
1.8 
1.1 
DTE Interface 
The ASM-60 DTE interface supports the following interfaces: 
•  HSSI 
•  IR-ETH module with built-in Ethernet bridge 
•  IR-ETH/QH module with built-in Fast Ethernet bridge and VLAN support 
•  IR-IP module with built-in IP router. 
Management 
Setup, control, monitoring of status and diagnostics can be performed using an 
ASCII terminal connected to the ASM-60 async DCE control port. 
Test Capabilities 
ASM-60 performs an extensive self-test at start-up. During the self-test, ASM-60 
checks its CPU, internal framer, DTE and interfaces and power supplies. The 
self-test results are displayed on the supervisory terminal. 
Real Time Alarms  
Real time alarms provide real time information on system status indicating loss of 
synchronization on line A and line B, DCD status etc.  
ASM-60 also features a log file that stores all alarms and events that occurred in the 
unit. These alarms can be displayed and cleared. 
Statistics Collection 
ASM-60 stores the VDSL statistics for the line performance monitoring.