RAD Data comm ASM-60 Manuel D’Utilisation

Page de 74
ASM-60 Installation and Operation Manual 
Appendix C  IR-IP Interface Module 
 
Erasing IR-IP Software 
C-29 
2.  Set all the four sections of IR-IP DIP switch to ON. 
3.  Turn the ASM-60 on and monitor the IP router ERR indicator: it must turn on 
and light steadily. 
4.  While the ERR indicator is lit (within 15 seconds), set sections 3 and 4 of IR-IP 
DIP switch to OFF. 
The IP router application software is erased. 
 
If you do not set sections 3 and 4 to OFF within 15 seconds of power-up, IR-IP 
ignores the setting of all the four sections to ON and starts normal operation. In this 
case, it is recommended to turn ASM-60 off and then back on. 
Alternately, to abort the whole operation, turn ASM-60 off, return all the four 
switches to the desired positions, and then turn ASM-60 on again. 
 
5.  Turn ASM-60 off, and the return all the four sections of the DIP switch to the 
desired positions. 
Downloading New Software 
After erasing the application software, you can download new software from any 
computer that can serve as a TFTP client. 
To enable the downloading, IR-IP automatically activates its TFTP server 
application with the following factory-default IP parameters: 
•  IP address: 
192.168.205.1 
•  Subnet mask: 
255.255.255.252. 
Connect the computer serving as a TFTP client to the IR-IP 10BASE-T connector in 
the way as a Telnet host used for preliminary configuration (see the Performing 
Preliminary Configuration section). The computer IP parameters must be 
configured as follows: 
•  IP address 
192.168.205.2 
•  Subnet mask 
255.255.255.252 
•  Default gateway 
192.168.205.1 
➤  To download new software: 
1.  If necessary, turn ASM-60 off. 
2.  Set all the four sections of the IR-IP DIP switch to OFF. 
3.  Turn ASM-60 on and monitor the ERR indicator: it must start flashing. 
4.  Connect the computer to the IP router LAN interface and configure its IP 
parameters as explained above. 
5.  Run a standard TFTP client application on the Telnet host, and download the 
appropriate software file. 
If the download is successful, IR-IP starts using the new software. 
If the downloading fails, repeat the download process. 
Note