IBM 500 Manuel D’Utilisation

Page de 63
SurePOS 500 4846-XX5 Technical Reference 
Page 36 of 63 
Susceptibility 
Air: Level 3 (8KV) 
Contact: Level 2 (4KV) 
Performance Criterion: B 
Electromagnetic Interference (EMI) 
FCC Part 15 Class A 
Canada EMI Class A (ICES-003) 
CISPR 22 Radiated Class A, Conducted Class B (EN55022): 1998 
VCCI Class  A 
Taiwan EMI CNS-13438 Class A 
Korea  EMI MIC Notice No. 1996-78 Class A 
New Zealand EMI Class A 
Australia EMI Class A  
Radiated Electromagnetic 
Susceptibility (RES) 
EN 50024: 1998 (EN61000-4-3) Criteria A 
Electrical Fast Transient/Power 
Line Transient (EFT/PLT) 
EN 50024: 1998 (EN61000-4-4) Criteria B 
 
Near Field Phenomena 
MPRII 
Power Line Disturbance/Ring 
EN50024: 1998 (EN 61000-4-11) 
 
Lightning Surge Susceptibility 
EN50024: 1998 (EN61000-4-5, Criteria B) 
 
Immunity to conducted 
disturbances 
EN55024:1998 
EN61000-4-6 Criteria A 
 
Power Frequency Magnetic Field 
Immunity 
EN55024:1998 
EN61000-4-8 Criteria A 
Power Line Harmonics 
(Power Correction Factor) 
EN 61000-3-2 
4.5.2  Ergonomics and accessibility 
Category Standard 
Flat Panel 
ISO/FDIS 13406-2, Flat Panel Standards 
Accessibility 
Section 508 of U.S. Rehabilitation Act